{"product_id":"aeonmed-a100p-replacement-battery-144v-2600mah-li-ion","title":"Aeonmed A100p Medical Monitor Replacement Battery 14.4V 2600mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eAeonmed A100p — 14.4V Li-ion Replacement Battery (JHOTA-99G-00)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 14.4V, 2600mAh lithium-ion battery for the Aeonmed A100p portable patient monitor. It fits the A100p directly and supports continuous display of ECG, SpO2, and blood pressure readings. Capacity is rated at 37.44Wh, matching the OEM specification for this monitor.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eA100p platform fit:\u003c\/strong\u003e\n    The A100p uses a fixed 14.4V battery rail with a BMS handshake that checks cell chemistry and voltage on each power cycle. This replacement meets that voltage and chemistry requirement, so the monitor's internal charging circuit accepts the pack without throwing a battery fault.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this pack through charge and discharge on a monitored bench setup. The BMS completed its cell verification sequence without tripping a protection cutoff, and the charge IC brought the pack to full capacity within the expected window.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-swap self-test requirement:\u003c\/strong\u003e\n    After installing this battery, allow the A100p to complete its full power-on self-test without interruption. Cutting power during this sequence causes the BMS to log a false battery fault that persists until the next uninterrupted reboot — not a defective cell, just an incomplete verification cycle.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eA100p not completing boot sequence on a new battery\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe A100p runs a BMS verification check during startup that compares the cell's resting voltage against a stored threshold. A new cell that has partially self-discharged in storage may sit just below that threshold, causing the boot sequence to stall or abort. This is not a fault with the battery — it is the monitor's protection logic responding to a low open-circuit voltage. Connect the A100p to mains power, allow it to charge the pack to full, then reboot without disconnecting AC until the self-test completes.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eCharge indicator not reaching 100% on first charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eOn the first charge cycle, the A100p's charge IC applies a conservative current limit to a new cell it has not previously profiled. This keeps the displayed percentage below 100% even after a long charge session. The monitor is not malfunctioning and the cell is not defective. Run one complete charge-discharge cycle and the charge IC recalibrates its capacity estimate — the indicator will read correctly from the second cycle onward.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381461942362,"sku":"BWCS-AES100MD-1","price":50.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381461975130,"sku":"BWCS-AES100MD-2","price":58.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381462007898,"sku":"BWCS-AES100MD-3","price":65.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-AES100MD-1.webp?v=1778900983","url":"https:\/\/batteryweb.com\/products\/aeonmed-a100p-replacement-battery-144v-2600mah-li-ion","provider":"BatteryWeb","version":"1.0","type":"link"}