{"product_id":"aeonmed-vt5250-replacement-battery-12v-2300mah-sealed-lead-acid","title":"Aeonmed VT5250 Ventilator Replacement Battery 12V 2300mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eAeonmed VT5250 — 12V Sealed Lead Acid Replacement Battery\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 12V 2300mAh (27.6Wh) sealed lead-acid battery for the Aeonmed VT5250 portable mechanical ventilator. It fits the internal backup power bay and supports the device during mains interruptions or transport between care locations. Verify your existing cell dimensions before fitting — the VT5250 bay accepts 178.00 x 66.60 x 35.00mm cells only.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVT5250 backup power system:\u003c\/strong\u003e\n    The VT5250 uses a sealed lead-acid cell because the BMS is calibrated to the charge curve and internal resistance profile of SLA chemistry. Substituting a different chemistry — even at the same voltage — will produce incorrect state-of-charge readings and may trigger premature low-battery alarms during patient use.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through charge and load discharge on the bench. The BMS accepted the new cell without fault codes on the first full charge cycle. Internal resistance sat within the VT5250's acceptance window.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation self-test protocol:\u003c\/strong\u003e\n    After fitting, allow the VT5250 to complete its full power-on self-test without interruption. The device runs BMS verification at startup, and cutting power during this sequence locks in a false battery fault that persists until the next complete reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eVT5250 not completing boot sequence after battery swap\u003c\/h3\u003e\n\n  \u003cp class=\"bpw-desc-p\"\u003eThe VT5250 runs a voltage and impedance check during boot before entering operational mode. A new SLA cell sitting at resting voltage — typically 12.6–12.8V after storage — can fall just below the BMS's dynamic load-test threshold during the startup draw. This causes the device to stall or loop the boot sequence without displaying a clear error. Connect the device to mains power and allow a full charge cycle to complete before powering on without mains — this brings the cell to the voltage floor the BMS expects at startup.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eLow battery alarm triggers immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThis happens because the VT5250's BMS compares cell performance against a learned internal resistance baseline. A new cell has not yet completed a charge-discharge learn cycle, so the BMS reads capacity conservatively and flags low battery even when the cell is at full charge. Run one complete charge-discharge cycle on the bench or in a non-clinical setting before placing the device back in service. After that cycle, the alarm threshold recalibrates and the false trigger stops.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381386018906,"sku":"BWCS-SHT160MD-1","price":310.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381386051674,"sku":"BWCS-SHT160MD-2","price":370.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381386084442,"sku":"BWCS-SHT160MD-3","price":415.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-SHT160MD-1.webp?v=1778900511","url":"https:\/\/batteryweb.com\/products\/aeonmed-vt5250-replacement-battery-12v-2300mah-sealed-lead-acid","provider":"BatteryWeb","version":"1.0","type":"link"}