{"product_id":"air-shields-vickers-minolta-replacement-battery-48v-500mah-ni-mh","title":"Minolta Jaundice Meter Replacement Battery 4.8V 500mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eAir Shields-Vickers Minolta Jaundice Meter — 4.8V Ni-MH Replacement Battery (120093)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 4.8V, 500mAh Ni-MH replacement battery for the Air Shields-Vickers Minolta Jaundice Meter. It replaces OEM part numbers 120093 and BATT\/110093. The cell pack matches the original voltage rail and connector configuration used in this clinical diagnostic instrument.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMinolta Jaundice Meter platform:\u003c\/strong\u003e\n    This meter draws a consistent low-current load during transcutaneous bilirubin readings. The 4.8V Ni-MH pack matches the voltage rail the device expects — substituting a different chemistry or voltage causes the BMS to flag a fault during the power-on self-test sequence.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell pack through charge and discharge on the bench. The BMS completed its initialisation handshake without fault flags. Cell voltage held within the expected window across multiple discharge cycles.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eFirst-use self-test protocol:\u003c\/strong\u003e\n    After installation, allow the device to complete its full power-on self-test without interruption. The Jaundice Meter runs a BMS verification routine at startup — cutting power mid-sequence plants a false battery fault that persists until the next complete reboot cycle.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eDevice not completing boot sequence after battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eA new Ni-MH cell pack at full charge can still fail the Jaundice Meter's internal voltage threshold check if the BMS has not yet completed a learn cycle. The device boot routine measures both resting voltage and internal resistance — a fresh cell straight from packaging may read slightly outside the calibrated OEM window. Run one full charge-discharge cycle before relying on the meter clinically. After that cycle, the BMS recalibrates its thresholds and the boot sequence completes normally.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eLow battery alarm triggers immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThis alarm is a BMS chemistry-check response, not a capacity failure. The Jaundice Meter's charge controller was calibrated to the discharge curve of the original OEM cell. A replacement cell presents a slightly different curve in the first few cycles, sitting just below the alarm threshold even at full charge. Complete one full charge-discharge cycle — the BMS re-maps the curve and the alarm clears. After conditioning, resting cell voltage should read at or above 4.8V before use.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381496873050,"sku":"BWCS-AHM093MD-1","price":24.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381496905818,"sku":"BWCS-AHM093MD-2","price":27.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381496938586,"sku":"BWCS-AHM093MD-3","price":30.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-AHM093MD-1.webp?v=1778901248","url":"https:\/\/batteryweb.com\/products\/air-shields-vickers-minolta-replacement-battery-48v-500mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}