{"product_id":"aspect-medical-system-bis-vista-monitoring-replacement-battery-74v-2600mah-li-ion","title":"Aspect Medical System BIS Vista 7.4V Replacement Battery 185-0152","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eAspect Medical System BIS Vista Monitoring System — 7.4V Li-ion Replacement Battery (185-0152)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 7.4V, 2600mAh Li-ion cell built to the same electrical spec as OEM part 185-0152. It fits the BIS Vista Monitoring System, Vista View BIS Monitor, and BIS Vista family of portable patient consciousness monitors. These devices are used in operating rooms and ICUs where a depleted battery mid-procedure is not an option.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBIS Vista platform compatibility:\u003c\/strong\u003e\n    The BIS Vista, Vista View, and BIS Vista Monitoring System all share the same 7.4V battery rail, connector pinout, and BMS handshake protocol — which is why a single cell covers the full model family listed above.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We ran this cell through charge, boot, and load cycles on BIS Vista hardware. The BMS accepted the cell on first insertion, completed the power-on self-test without fault flags, and held voltage within spec under the monitor's active measurement load.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eFirst-use protocol on medical equipment:\u003c\/strong\u003e\n    After installation, allow the device to complete its full power-on self-test cycle without interruption. The BIS Vista runs BMS verification at startup — cutting power during this sequence triggers a false battery fault that persists until the next clean reboot. Let the test finish before proceeding to clinical use.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eBIS Vista not completing boot sequence after battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe BIS Vista runs a multi-step BMS verification during boot. A new cell that hasn't completed its first full charge-discharge cycle may not yet meet the BMS's internal state-of-charge threshold for a clean self-test pass. This causes the device to stall or loop during startup rather than reach the monitoring screen. Run one full charge cycle on the new cell before attempting clinical use — the BMS learn cycle completes during that first full discharge, and subsequent boots proceed normally.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eBIS Vista alarming low battery immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThis happens because the device's charge IC applies a conservative upper voltage limit on a new cell during the first charge — the cell doesn't reach the same state-of-charge profile the BMS expects from a conditioned OEM cell. The low battery alarm threshold is calibrated to that known profile. One complete charge-discharge cycle recalibrates the BMS's fuel gauge to the actual cell capacity. After that first cycle, the alarm clears and the charge indicator behaves normally at full charge.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381481767002,"sku":"BWCS-AMS456MD-1","price":34.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381481799770,"sku":"BWCS-AMS456MD-2","price":39.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381481832538,"sku":"BWCS-AMS456MD-3","price":43.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-AMS456MD-1.webp?v=1778901170","url":"https:\/\/batteryweb.com\/products\/aspect-medical-system-bis-vista-monitoring-replacement-battery-74v-2600mah-li-ion","provider":"BatteryWeb","version":"1.0","type":"link"}