{"product_id":"aspen-labs-zimmer-ats-1200-replacement-battery-12v-2300mah-sealed-lead-acid","title":"ASPEN LABS ZIMMER ATS 1200 Replacement Battery 12V 2300mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eASPEN LABS ZIMMER ATS 1200 \/ ATS 2000 Series — 12V Sealed Lead Acid Replacement Battery (60-7000-027)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 12V, 2300mAh (27.6Wh) sealed lead-acid replacement battery for the ASPEN LABS ZIMMER ATS tourniquet series. It fits the ATS 1000, ATS 1200, ATS 1500, and ATS 2000 automated tourniquet systems used in surgical environments to control cuff inflation and deflation. Voltage and capacity match OEM specifications exactly.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eATS 1000 \/ 1200 \/ 1500 \/ 2000 platform compatibility:\u003c\/strong\u003e\n    These four models share the same 12V SLA battery bay, connector pinout, and internal BMS handshake requirements. The 60-7000-027 part number spans the full ATS line — one battery cell architecture covers all four variants.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We ran this cell through charge and load cycles on the ATS platform. The BMS accepted the new cell without error flags, and the charge IC held within the expected absorption voltage window for sealed lead-acid chemistry at 12V.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-swap self-test protocol:\u003c\/strong\u003e\n    After installing this battery, allow the ATS device to complete its full power-on self-test cycle without interruption. The ATS runs a BMS verification routine at startup — cutting power during this sequence causes a false battery fault that persists until the next full reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eATS tourniquet not completing boot sequence after battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe ATS series runs a voltage threshold check during its boot sequence. A new sealed lead-acid cell often rests below 12.4V after shipping, which is enough to trip the boot self-test and halt the startup routine. This is a resting voltage issue, not a faulty cell. Charge the battery fully before the first installation — a healthy SLA cell at full charge should read between 12.7V and 12.9V open-circuit before insertion.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eATS tourniquet alarming low battery immediately after confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe ATS BMS calibrates its state-of-charge thresholds against the cell's actual capacity, and a new SLA cell hasn't yet established its capacity baseline. On the first cycle, the BMS may read the cell as undercharged even when the charger shows complete. Run one full charge-discharge-recharge cycle before clinical use. After that cycle, the BMS recalibrates and the low-battery alarm clears at the correct threshold.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381385723994,"sku":"BWCS-SHT160MD-1","price":310.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381385756762,"sku":"BWCS-SHT160MD-2","price":370.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381385789530,"sku":"BWCS-SHT160MD-3","price":415.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-SHT160MD-1.webp?v=1778900511","url":"https:\/\/batteryweb.com\/products\/aspen-labs-zimmer-ats-1200-replacement-battery-12v-2300mah-sealed-lead-acid","provider":"BatteryWeb","version":"1.0","type":"link"}