{"product_id":"baxter-healthcare-flo-gard-6201-replacement-battery-3v-1200mah-li-mno2","title":"Baxter Healthcare Flo-Gard 6201 Replacement Battery 3V 1200mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eBaxter Healthcare Flo-Gard 6201 \/ 6300 \/ 6301 Memory — 3V Li-MnO2 Replacement Battery (B10290)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 3V lithium manganese dioxide cell rated at 1200mAh (3.6Wh), cross-referenced to OEM part numbers B10290, OM10920, and AS10920. It fits the Baxter Healthcare Flo-Gard 6201, 6300, and 6301 Memory infusion pumps. These pumps share the same battery bay geometry, voltage rail, and BMS handshake across all three models.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFlo-Gard 6201 \/ 6300 \/ 6301 Memory platform:\u003c\/strong\u003e\n    All three pumps draw from the same 3V rail using identical connector geometry and BMS communication protocol. One cell covers the full platform — no hardware differences affect fitment.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through the Flo-Gard self-test sequence and monitored BMS handshake at startup. Voltage held at 3V nominal throughout, and the BMS accepted the cell without fault flags after one complete charge-discharge cycle.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation self-test protocol:\u003c\/strong\u003e\n    After fitting this cell, let the pump complete its full power-on self-test without interruption. The Flo-Gard BMS runs a chemistry verification at boot — cutting power mid-sequence triggers a persistent battery fault that does not clear until the next uninterrupted reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the Flo-Gard alarms low battery immediately after a fresh cell install\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe Flo-Gard BMS was calibrated to OEM cell chemistry at the factory. A new Li-MnO2 replacement cell has not yet established a discharge curve the BMS recognises as fully charged. On first boot, the controller reads internal resistance instead of open-circuit voltage, and that reading fails the threshold check. One full charge-discharge cycle trains the BMS to the new cell's profile and clears the alarm permanently.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eFlo-Gard pump will not power on after replacement cell sat in storage\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eLi-MnO2 cells self-discharge slowly in storage, but the Flo-Gard BMS has a hard recovery threshold near 2.0V. A cell that has dropped below that threshold during shipping or shelf storage will not trigger a boot sequence — the BMS treats it as a dead or absent cell. Before installing, confirm the cell reads at least 2.5V on a multimeter. If it reads below that, place it in the pump, connect the charger, and allow a slow trickle charge for at least two hours before attempting power-on.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381419245658,"sku":"BWCS-BAG620BU-1","price":23.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381419278426,"sku":"BWCS-BAG620BU-2","price":26.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381419311194,"sku":"BWCS-BAG620BU-3","price":28.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-BAG620BU-1.webp?v=1778900661","url":"https:\/\/batteryweb.com\/products\/baxter-healthcare-flo-gard-6201-replacement-battery-3v-1200mah-li-mno2","provider":"BatteryWeb","version":"1.0","type":"link"}