{"product_id":"bio-logic-devices-analyzer-rf303-replacement-battery-12v-2300mah-sealed-lead-acid","title":"BIO LOGIC DEVICES Analyzer RF303 12V Replacement Battery 2300mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eBIO LOGIC DEVICES Analyzer RF303 — 12V Sealed Lead Acid Replacement Battery\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 12V, 2300mAh (27.6Wh) sealed lead-acid battery for the BIO LOGIC DEVICES Analyzer RF303 portable cardiac and respiratory diagnostic instrument. It replaces the internal SLA cell that powers the analyzer during patient examinations. Voltage, capacity, and physical dimensions (178.00 × 66.60 × 35.00mm) match the original cell.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAnalyzer RF303 fit:\u003c\/strong\u003e\n    The RF303 runs a 12V SLA power rail with a BMS that expects sealed lead-acid charge curve behaviour. Substituting a different chemistry causes the charge IC to apply the wrong voltage ceiling, which trips a battery fault on the internal self-test.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through the RF303 power-on sequence and verified BMS handshake, charge acceptance, and discharge response under the analyzer's load profile. The cell passed self-test after one full charge-discharge cycle.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eFirst-install sequence for the RF303:\u003c\/strong\u003e\n    After fitting this battery, allow the device to complete its full power-on self-test without interruption. The RF303 runs BMS verification at startup — cutting power mid-sequence registers a false battery fault that persists until the next clean reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the RF303 may not complete its boot sequence on a new battery\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe RF303 checks resting voltage and internal resistance during boot before allowing clinical operation. A new SLA cell that has been in storage will show a suppressed resting voltage even after surface charge — typically sitting below 12.4V when the BMS expects 12.6V or higher. The device interprets this as a depleted or faulty cell and halts the boot sequence. Run one full charge cycle to 12.7–12.8V before the first clinical use to clear this condition.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eLow battery alarm triggering immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThis happens when the BMS threshold was calibrated to the internal resistance profile of the original aged cell. A fresh SLA cell has lower internal resistance and a slightly different discharge curve, which the BMS may score below its alarm threshold on the first capacity verification pass. The alarm clears once the battery completes one full charge-discharge cycle and the BMS recalibrates its state-of-charge model. Discharge to approximately 11.8V under normal analyzer load, then charge fully before returning the device to clinical use.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381388542042,"sku":"BWCS-SHT160MD-1","price":310.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381388574810,"sku":"BWCS-SHT160MD-2","price":370.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381388607578,"sku":"BWCS-SHT160MD-3","price":415.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-SHT160MD-1.webp?v=1778900511","url":"https:\/\/batteryweb.com\/products\/bio-logic-devices-analyzer-rf303-replacement-battery-12v-2300mah-sealed-lead-acid","provider":"BatteryWeb","version":"1.0","type":"link"}