{"product_id":"biocare-ie3000-replacement-battery-111v-2600mah-li-ion","title":"Biocare iE3000 HYLB-1994 Replacement Battery 11.1V 2600mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eBiocare iE3000 \/ iE101 — 11.1V Li-ion Replacement Battery (HYLB-1994)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is an 11.1V 2600mAh (28.86Wh) lithium-ion battery for the Biocare iE3000 and iE101 portable medical diagnostic instruments. It replaces OEM part numbers HYLB-1994 and 02030046. Physical dimensions are 68.60 × 55.20 × 18.60mm — confirm these against your existing cell before fitting.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eiE3000 and iE101 compatibility:\u003c\/strong\u003e\n    Both models run the same 11.1V three-cell series architecture with an identical connector pinout and BMS handshake protocol. One battery covers both platforms without modification.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through full charge and discharge on the iE3000 platform and confirmed the BMS accepted the cell, passed the charge-complete flag, and held voltage within spec under the device's diagnostic load profile.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePower-on self-test after installation:\u003c\/strong\u003e\n    After fitting this battery, let the iE3000 or iE101 complete its full startup self-test without interrupting power. Medical device BMS firmware runs a battery verification routine at boot. Cutting power mid-sequence flags a persistent battery fault that will not clear until the next clean reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the iE3000 rejects a new battery during self-test\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe iE3000's BMS uses a learned capacity threshold set against OEM cell chemistry. A fresh replacement cell has not yet completed a full charge-discharge cycle, so its reported state-of-charge profile does not match the stored baseline. The device interprets this mismatch as a fault and may display a battery error or refuse to proceed past the self-test screen. Running one complete charge cycle — to full charge termination, then to normal discharge cutoff at approximately 9V — writes the correct capacity data to the BMS and clears this condition.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eCharge indicator stuck below 100% after fitting a new cell\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eOn first charge, the iE3000's charge IC applies a conservative current limit to an unrecognised cell, which causes the charge cycle to terminate early before the cell reaches full capacity. The indicator reads 85–95% and stops climbing. This is a charge IC protection behaviour, not a faulty battery. Connect the device to mains power and allow a second full charge cycle — the IC adjusts its termination threshold once it has profiled the new cell, and the indicator will reach 100%.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381403975770,"sku":"BWCS-BCE300MD-1","price":75.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381404008538,"sku":"BWCS-BCE300MD-2","price":89.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381404041306,"sku":"BWCS-BCE300MD-3","price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-BCE300MD-1.webp?v=1778900597","url":"https:\/\/batteryweb.com\/products\/biocare-ie3000-replacement-battery-111v-2600mah-li-ion","provider":"BatteryWeb","version":"1.0","type":"link"}