{"product_id":"biolight-m10-replacement-battery-111v-2600mah-li-ion","title":"Biolight M10 Patient Monitor Replacement Battery 11.1V 2600mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eBiolight M10 \/ S10 \/ M12 Overview Patient Monitor — 11.1V Li-ion Replacement Battery (LIS12001A-3IXR19\/65)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is an 11.1V, 2600mAh Li-ion replacement battery for the Biolight M10, S10, M10 Overview, and M12 Overview patient monitors. These portable clinical monitors use this battery during bedside assessments and patient transport. Voltage, connector, and BMS communication match the OEM specification.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eM10, S10, M12 Overview compatibility:\u003c\/strong\u003e\n    These monitors share the same 11.1V three-cell Li-ion architecture, connector pinout, and BMS handshake protocol — that is why a single part number covers the entire product family. The cell configuration and protection circuit are identical across all listed models.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We ran this cell through the M10 power-on sequence and monitored BMS communication at startup. The protection circuit responded correctly to the device's charge-status query, and the monitor reported accurate state-of-charge after one full charge-discharge cycle.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation startup sequence:\u003c\/strong\u003e\n    After fitting this battery, allow the monitor to complete its full power-on self-test without interruption. The device runs a BMS verification step at boot — cutting power mid-sequence triggers a false battery fault that latches until the next clean reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eDevice not completing boot sequence after battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe M10 and M12 Overview monitors run a multi-step BMS verification at power-on before the main display initialises. A new cell that has not completed its first full charge-discharge cycle may report a state-of-charge value the device's charge IC flags as out-of-expected-range. This causes the boot sequence to halt before the vital-signs screen loads. Run one full charge cycle to 100% and discharge under normal monitoring load before clinical use — this allows the BMS to calibrate its capacity estimate correctly.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eLow battery alarm triggering immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThis happens because the monitor's alarm threshold is calibrated against the OEM cell's charge curve — a new replacement cell presents a slightly different voltage-to-capacity curve in its first few cycles. The device reads the voltage correctly but maps it to a lower apparent capacity, triggering the alarm prematurely. It is not a fault with the replacement cell. Complete one full charge-discharge cycle and recharge to 100%; the alarm threshold should clear once the BMS has a full cycle of data to reference.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381403779162,"sku":"BWCS-BLS100MD-1","price":75.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381403811930,"sku":"BWCS-BLS100MD-2","price":89.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381403844698,"sku":"BWCS-BLS100MD-3","price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-BLS100MD-1.webp?v=1778900597","url":"https:\/\/batteryweb.com\/products\/biolight-m10-replacement-battery-111v-2600mah-li-ion","provider":"BatteryWeb","version":"1.0","type":"link"}