{"product_id":"biwater-aqua-monitor-replacement-battery-12v-3000mah-ni-mh","title":"BIWATER AQUA Monitor E-1502 12V Replacement Battery","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eBIWATER AQUA Monitor — 12V Ni-MH Replacement Battery (E-1502)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 12V, 3000mAh Ni-MH replacement battery for the BIWATER AQUA Monitor water quality testing device (Part No E-1502). It powers the monitor's sensors and display during active water parameter testing. Dimensions are 112.00 x 46.00 x 44.60mm — confirm physical fitment before installation.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAQUA Monitor power rail:\u003c\/strong\u003e\n    The AQUA Monitor runs its sensor array and display from a single 12V Ni-MH pack. The device's BMS is matched to Ni-MH discharge curves — voltage sag behavior and charge termination thresholds are both chemistry-specific here, so substituting a different chemistry will cause false low-battery faults.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through charge and load discharge while monitoring BMS handshake signals. The protection circuit accepted charge termination cleanly at peak delta-V, and the cell held stable voltage under the sensor and display load profile without triggering cutoff.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-swap startup protocol:\u003c\/strong\u003e\n    After installing this battery, let the AQUA Monitor complete its full power-on self-test without interruption. Medical-grade devices run a BMS verification sequence at boot — cutting power mid-sequence registers a battery fault that persists until the next clean reboot cycle.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eAQUA Monitor not completing boot sequence after battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe AQUA Monitor runs a startup verification sequence that checks cell voltage against an OEM-calibrated threshold. A new Ni-MH cell that has partially self-discharged during storage may read below that threshold even though the cell itself is healthy. If the device stalls or loops at boot, charge the battery fully before attempting another power-on. One complete charge-discharge cycle allows the BMS to recognise the cell's actual capacity and pass the boot check.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eCharge indicator not reaching 100% on the first charge cycle\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eNi-MH charge ICs apply a conservative charge limit on unfamiliar cells — the device's charge controller looks for a peak delta-V signal to confirm full charge, and a new cell's voltage curve can be shallower than expected on the first cycle. This causes the indicator to plateau early rather than reach 100%. Run a full charge followed by a normal discharge under device load, then recharge. By the second or third cycle the delta-V signal is strong enough for the controller to register a complete charge correctly.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381457518682,"sku":"BWCS-BTM150MD-1","price":102.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381457551450,"sku":"BWCS-BTM150MD-2","price":118.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381457584218,"sku":"BWCS-BTM150MD-3","price":129.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-BTM150MD-1.webp?v=1778900983","url":"https:\/\/batteryweb.com\/products\/biwater-aqua-monitor-replacement-battery-12v-3000mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}