{"product_id":"clinical-dynamics-nibp-gx-2-replacement-battery-192v-2500mah-ni-mh","title":"Clinical Dynamics NIBP GX-2 Replacement Battery 19.2V 2500mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eClinical Dynamics NIBP GX-2 Series — 19.2V Ni-MH Replacement Battery (460005-078)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 19.2V, 2500mAh Ni-MH replacement battery for the Clinical Dynamics NIBP GX-2 non-invasive blood pressure monitor. It also fits the GX-2 Smart Arm, SS100A Smart Sat, and Smartarm SPO2, among others. OEM part numbers covered include 460005-078, BATT\/110476, AS10973, B10973, OM10973, and MB210B.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGX-2 and Smart Arm platform fitment:\u003c\/strong\u003e\n    These models share the same 19.2V power rail, connector pinout, and BMS handshake protocol. One cell pack covers the full group — no adapter or modification needed.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this pack through charge and discharge on the GX-2 platform. The BMS handshake initialised cleanly, charge acceptance was normal from the first cycle, and the device completed its power-on self-test without fault codes.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-swap startup protocol for clinical equipment:\u003c\/strong\u003e\n    After installing this battery, let the device complete its full power-on self-test without interruption. The GX-2 runs a BMS verification sequence at startup. Interrupting it — even once — can lock in a false battery fault that only clears on a clean reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the GX-2 reports low battery immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe GX-2's charge IC applies a conservative acceptance threshold that new Ni-MH cells don't meet on the first cycle. The BMS is calibrated to the internal resistance profile of a conditioned cell — a fresh pack reads slightly outside that window. After one complete charge-discharge cycle, the cell's internal resistance drops into the expected range and the alarm clears. Do not use the device in a clinical setting until that first conditioning cycle is complete.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eGX-2 not powering on after the battery sat in storage\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eNi-MH cells self-discharge at roughly 1–2% per day. A pack that has been in storage for several weeks can drop below the GX-2's BMS recovery threshold — typically around 14–15V on a 19.2V Ni-MH pack — and the device will not boot. Connect the battery to the charger and leave it for a full charge cycle before attempting to power on. If the charger shows no activity after 30 minutes, the cell voltage may be too low for the charge IC to detect; remove and reinsert the pack to force a re-detection attempt.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381491957850,"sku":"BWCS-CDN200MD-1","price":84.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381491990618,"sku":"BWCS-CDN200MD-2","price":98.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381492023386,"sku":"BWCS-CDN200MD-3","price":109.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-CDN200MD-1.webp?v=1778901249","url":"https:\/\/batteryweb.com\/products\/clinical-dynamics-nibp-gx-2-replacement-battery-192v-2500mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}