{"product_id":"codan-argus-606-s-syringe-pump-replacement-battery-12v-2000mah-ni-mh","title":"Codan Argus 606 S Compatible Battery 12V 2000mAh Ni-MH","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eCodan Argus 606 S Syringe Pump — 12V Ni-MH Replacement Battery (110840-O)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 12V 2000mAh Ni-MH replacement battery for the Codan Argus 606 S Syringe Pump and Argus infusion pump 606. It replaces OEM part numbers 110840-O and 601260. The battery fits directly into the pump's battery bay at the same voltage and capacity as the original cell pack.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eArgus 606 S and 606 platform compatibility:\u003c\/strong\u003e\n    Both Argus 606 variants share the same 12V battery rail, connector pinout, and BMS handshake protocol. A single cell pack covers both designations without modification.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this battery through the Argus 606 S charge and discharge sequence. The BMS accepted the cell, completed the charge cycle without flagging a chemistry mismatch, and held voltage within the expected window across multiple discharge runs.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation self-test protocol:\u003c\/strong\u003e\n    After fitting this battery, let the pump complete its full power-on self-test without interruption. The Argus 606 S runs a BMS verification sequence at startup — cutting power during this window stores a false battery fault that persists until the next full reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the Argus 606 S self-test fails after a battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe Argus 606 S BMS runs a learn cycle when it first encounters a new cell. On the initial charge, the charge IC applies a conservative current limit while it profiles the new Ni-MH pack. If the pump is powered down mid-cycle or the self-test is interrupted, the BMS logs an incomplete verification and will continue to flag battery faults on subsequent boots. Run one complete charge-discharge cycle before placing the pump in clinical use — this lets the BMS complete its calibration pass and clear any pending fault flags.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eCharge indicator not reaching 100% on first charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eOn a fresh Ni-MH cell, the Argus 606 S charge controller holds back the final charge increment until it confirms the pack's temperature and delta-V signature match expected values. A new cell's internal resistance reads slightly higher than a conditioned pack, which causes the controller to interpret full charge as not yet reached. This is not a fault — it resolves after the first complete charge cycle once the BMS has mapped the cell's actual response curve. After that first cycle, the indicator will reach 100% and hold normally.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381364523098,"sku":"BWCS-CRP606MD-1","price":76.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381364555866,"sku":"BWCS-CRP606MD-2","price":90.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381364588634,"sku":"BWCS-CRP606MD-3","price":101.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-CRP606MD-1.webp?v=1778900267","url":"https:\/\/batteryweb.com\/products\/codan-argus-606-s-syringe-pump-replacement-battery-12v-2000mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}