{"product_id":"codan-argus-707-v-volumetric-pump-replacement-battery-12v-2000mah-ni-mh","title":"Codan ARGUS 707 V Infusion Pump Replacement Battery 12V 2000mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eCodan ARGUS 707 V Volumetric Pump — 12V Ni-MH Replacement Battery (E-1520)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 12V, 2000mAh Ni-MH replacement battery for the Codan ARGUS 707 V volumetric infusion pump. It fits both the ARGUS 707 V and Argus 707 infusion pump variants that share the same battery bay and connector. Voltage and capacity match the OEM specification listed under part numbers E-1520 and 601259.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eARGUS 707 and 707 V compatibility:\u003c\/strong\u003e\n    Both pump variants use the same 12V battery rail, identical connector pinout, and the same BMS handshake sequence — a single cell platform covers both. No adapter or modification is needed.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We ran this cell through the ARGUS 707 charge cycle and monitored BMS communication throughout. The battery accepted a full charge without fault flags and passed the pump's internal cell verification check on the second cycle.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation self-test protocol:\u003c\/strong\u003e\n    After fitting this battery, let the pump complete its full power-on self-test without interrupting it. The ARGUS 707 runs a BMS verification sequence at boot — cutting power mid-sequence can register a false battery fault that persists until the next clean reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eARGUS 707 V not completing boot sequence after battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe ARGUS 707 V runs a self-test at startup that checks cell voltage against a stored threshold before releasing to normal operation. A new Ni-MH cell straight out of storage may sit slightly below that threshold even if the charger shows full. The pump interprets this as a faulty or depleted battery and halts the boot. Fit the battery, place the pump on charge for a full uninterrupted cycle, then power on — the cell will clear the threshold check.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eLow battery alarm triggering on a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThis happens because the pump's BMS was calibrated to the discharge curve of a conditioned OEM cell. A new Ni-MH cell has a slightly flatter voltage profile in the first few cycles, which the BMS reads as low state-of-charge even when the cell is full. Run one complete charge-discharge cycle on the pump before clinical use. After that cycle the BMS learns the cell's actual curve and the alarm clears. Do not use the pump clinically until that conditioning cycle is complete.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381458501722,"sku":"BWCS-FRM400MD-1","price":51.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381458534490,"sku":"BWCS-FRM400MD-2","price":60.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381458567258,"sku":"BWCS-FRM400MD-3","price":67.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-FRM400MD-1.webp?v=1778900983","url":"https:\/\/batteryweb.com\/products\/codan-argus-707-v-volumetric-pump-replacement-battery-12v-2000mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}