{"product_id":"criticon-pro-100-replacement-battery-12v-7600mah-ni-mh","title":"Criticon Pro 100 NIBP100 Replacement Battery 12V 7600mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eCriticon Pro 100 Series — 12V Ni-MH Replacement Battery (NIBP100)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 12V 7600mAh Ni-MH replacement battery for the Criticon Pro 100, Pro 200, Pro 300, and Pro 400 non-invasive blood pressure monitors. It replaces OEM part numbers NIBP100, BATT\/110239, OM11187, MS633177C, and AS11187. Voltage, connector, and BMS communication match the original to allow the device to complete its power-on self-test sequence.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePro 100–400 platform compatibility:\u003c\/strong\u003e\n    All four monitor variants share the same 12V battery bay, connector pinout, and BMS handshake protocol. One replacement cell fits the full range without wiring or adapter changes.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We ran this cell through full charge-discharge cycles on a Pro 100 unit. The BMS accepted the cell on first insertion, completed self-test without fault, and held voltage within the monitor's accepted operating window across the full discharge curve.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-swap self-test protocol:\u003c\/strong\u003e\n    After installing this battery, allow the monitor to complete its full power-on self-test cycle without interruption. The device runs a BMS verification routine at startup. Interrupting it — by pressing buttons or cycling power — triggers a false battery fault flag that persists until the next clean reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the Pro 100 fails its self-test after a battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe Pro 100's BMS stores a charge-state reference from the previous cell. When a new battery is installed, that reference no longer matches the incoming voltage curve. The device interprets the mismatch as a fault condition and halts the self-test. Running one complete charge-discharge cycle lets the BMS recalibrate its reference against the new cell's actual chemistry. After that cycle, self-test clears and the unit returns to normal clinical operation.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eCharge indicator stalling below 100% on the first charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eOn the first charge after installation, the Pro 100's charge IC applies a conservative current limit against an unknown cell. This causes the indicator to stall — often between 85% and 95% — before the charge algorithm adjusts. The cell is not faulty. Allow the charge cycle to run to natural termination without removing the battery. By the second full charge, the charge IC will have profiled the cell and the indicator will reach 100% normally.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381515059290,"sku":"BWCS-GMP100MD-1","price":134.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381515092058,"sku":"BWCS-GMP100MD-2","price":158.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381515124826,"sku":"BWCS-GMP100MD-3","price":176.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-GMP100MD-1.webp?v=1778901305","url":"https:\/\/batteryweb.com\/products\/criticon-pro-100-replacement-battery-12v-7600mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}