{"product_id":"datex-ohmeda-pulse-oximeter-biox-3770-replacement-battery-96v-2500mah-ni-mh","title":"Datex Ohmeda Pulse Oximeter Biox 3770 Replacement Battery 9.6V 2500mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eDatex Ohmeda Pulse Oximeter Biox 3770 \/ 3775 — 9.6V Ni-MH Replacement Battery (120109)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis 9.6V 2500mAh Ni-MH battery replaces the original power cell in the Datex Ohmeda Biox 3770 and Biox 3775 pulse oximeters. These bedside units monitor patient SpO₂ and heart rate in clinical settings, where a failing battery interrupts continuous monitoring. Voltage and cell count match the OEM specification to maintain normal BMS communication at startup.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBiox 3770 and 3775 compatibility:\u003c\/strong\u003e\n    Both models share the same battery bay geometry, connector pinout, and 9.6V rail. The charge IC on each unit reads the same thermistor signal, so the BMS handshake runs identically across both platforms.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We ran the battery through a full charge-discharge cycle on a Biox-series unit and confirmed the BMS accepted the cell, completed its self-test, and logged no fault codes. Charge acceptance and termination voltage were within OEM tolerance.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation self-test protocol:\u003c\/strong\u003e\n    After fitting this battery, let the device run its full power-on self-test without interruption. The Biox 3770 and 3775 both run a BMS verification pass at boot — cutting power during that sequence writes a fault flag that persists until the next complete reboot cycle.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eBiox 3770 not completing boot sequence on a new battery\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe Biox 3770 runs a hardware self-test during every power-on cycle, and the BMS checks cell voltage before allowing the unit to proceed past the initialisation screen. A new Ni-MH cell fresh from storage may sit at a resting voltage slightly below the BMS acceptance threshold, even if the cell is not depleted. The fix is to charge the battery fully in the device before the first clinical use — one complete charge cycle brings resting voltage into the range the BMS expects. If the unit still stalls at boot after a full charge, check that the battery contacts are clean and seating flush in the bay.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eLow battery alarm triggers immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThis happens because the Biox charge IC sets its low-battery threshold based on the discharge curve it learned from the previous cell. A fresh Ni-MH cell has not yet established its internal resistance baseline, so the device under-reads available capacity on the first one or two cycles. The alarm clears after one full charge-discharge cycle, which lets the BMS recalibrate its capacity estimate against the new cell's actual curve. Run the battery to the low-battery cutoff once, recharge fully, and the alarm threshold will align correctly before clinical deployment.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381493399642,"sku":"BWCS-DHP377MD-1","price":55.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381493432410,"sku":"BWCS-DHP377MD-2","price":65.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381493465178,"sku":"BWCS-DHP377MD-3","price":72.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-DHP377MD-1.webp?v=1778901265","url":"https:\/\/batteryweb.com\/products\/datex-ohmeda-pulse-oximeter-biox-3770-replacement-battery-96v-2500mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}