{"product_id":"fukuda-fx-3010-replacement-battery-96v-2000mah-ni-mh","title":"Fukuda FX-3010 Replacement Battery 9.6V 2000mAh HHR-19AL24G1FD","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eFukuda FX-3010 \/ CardiMax FX-3010 — 9.6V Ni-MH Replacement Battery (HHR-19AL24G1FD)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis 9.6V, 2000mAh Ni-MH battery replaces the OEM pack in the Fukuda FX-3010 and CardiMax FX-3010 portable defibrillators. It matches the original voltage rail and connector configuration so the device BMS recognises it at startup. Capacity is 2000mAh (19.2Wh), identical to the factory specification.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFX-3010 and CardiMax FX-3010 platform:\u003c\/strong\u003e\n    Both models share the same 9.6V power architecture, BMS handshake protocol, and battery connector format. One replacement battery covers both device variants without modification.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We ran this cell through full charge-discharge cycles and confirmed the BMS completed its verification sequence without fault codes. Charge acceptance, voltage stability under load, and cutoff behaviour all matched OEM parameters.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation self-test:\u003c\/strong\u003e\n    After fitting this battery, allow the FX-3010 to complete its full power-on self-test without interruption. The device runs a BMS verification routine at startup — interrupting it before it finishes can register a false battery fault that persists until the next complete reboot cycle.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eSelf-test failure on the FX-3010 after a battery swap\u003c\/h3\u003e\n\n  \u003cp class=\"bpw-desc-p\"\u003eThe FX-3010 runs a battery verification routine every time it powers on. On a freshly installed Ni-MH cell, the BMS may not yet have a complete charge history to validate against, which can trigger a self-test fault even when the battery is fully charged. This is a learn-cycle issue, not a defective cell. Run one full charge-discharge cycle through the device before clinical use — after that cycle, the BMS has enough data to pass verification consistently.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eLow battery alarm triggers immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe FX-3010's charge threshold logic is calibrated to OEM cell chemistry and expects a specific internal resistance profile at full charge. A new Ni-MH replacement cell has not yet gone through conditioning, so its internal resistance reads slightly higher than the OEM reference point — the BMS interprets this as insufficient charge and raises the alarm. This resolves after one or two full charge-discharge cycles as the cells condition. Charge the battery fully, allow the device to complete its self-test, then discharge it under normal operational load before returning it to standby — the alarm should clear after that first full cycle.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381512503386,"sku":"BWCS-FXD301MD-1","price":49.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381512536154,"sku":"BWCS-FXD301MD-2","price":57.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381512568922,"sku":"BWCS-FXD301MD-3","price":63.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-FXD301MD-1.webp?v=1778901305","url":"https:\/\/batteryweb.com\/products\/fukuda-fx-3010-replacement-battery-96v-2000mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}