{"product_id":"fukuda-fx-7302-replacement-battery-96v-4000mah-ni-mh","title":"Fukuda FX-7302 Replacement Battery 9.6V 4000mAh Ni-MH","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eFukuda FX-7302 \/ CardiMax FCP-7101 — 9.6V Ni-MH Replacement Battery (8PHR)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis 9.6V, 4000mAh Ni-MH battery replaces the original pack in the Fukuda FX-7302, Cardimax FX-7302, CardiMax FCP-7101, and FX-7402 electrocardiograph units. These are portable ECG machines used in clinical wards, cardiac departments, and ambulances. It matches the OEM voltage rail and connector pinout for these models.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFX-7302 and FCP-7101 compatibility:\u003c\/strong\u003e\n    Both units share the same 9.6V battery bay, connector latch, and BMS handshake protocol. The 8PHR and T8HR4\/3FAUC-5345 part numbers cover all four listed Fukuda ECG models without modification.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through full charge and discharge on the FX-7302 platform. The BMS accepted the cell on first insertion and completed the onboard verification sequence without fault codes.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation self-test protocol:\u003c\/strong\u003e\n    After fitting this battery, let the device complete its full power-on self-test without interrupting the boot sequence. The FX-7302 runs a BMS verification pass at startup — cutting power mid-cycle triggers a false battery fault that persists until the next complete reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the FX-7302 flags a battery fault after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe FX-7302 BMS stores a capacity baseline from the previous cell. A new Ni-MH pack reads differently on the first few cycles because the cells haven't reached full electrochemical conditioning. The device compares current charge acceptance against that stored baseline and raises a fault if the figures don't align. Running one complete charge-discharge cycle resets the learned threshold and clears the fault on subsequent boots.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eECG unit powers on but shuts off unexpectedly during patient recording\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eDuring the first ten cycles, a new Ni-MH cell delivers slightly lower sustained voltage under the ECG's active recording load. The FX-7302 power management circuit has a tight low-voltage cutoff — it protects the acquisition hardware by shutting down before voltage drops affect signal integrity. This is not a faulty battery. Capacity stabilises after several full cycles, and the cutoff trips less frequently as the cell conditions. Confirm the battery has reached at least 9.0V under load before marking the unit unserviceable.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381521088602,"sku":"BWCS-FXD730MD-1","price":77.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381521121370,"sku":"BWCS-FXD730MD-2","price":89.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381521154138,"sku":"BWCS-FXD730MD-3","price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-FXD730MD-1.webp?v=1778901370","url":"https:\/\/batteryweb.com\/products\/fukuda-fx-7302-replacement-battery-96v-4000mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}