{"product_id":"ge-datex-ohmeda-anesthesia-7800-ventilator-replacement-battery-48v-3600mah-ni-mh","title":"GE Datex Ohmeda 7800 Ventilator Compatible Battery 4.8V 3600mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eGE Datex Ohmeda Anesthesia 7800 Ventilator — 4.8V Ni-MH Replacement Battery\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis 4.8V Ni-MH battery replaces the internal backup cell in the GE Datex Ohmeda Anesthesia 7800 Ventilator and the Ohmeda Respirator Excel 7800. It provides backup power to sustain ventilation function during mains interruptions in surgical settings. Capacity is 3600mAh (17.28Wh), matching the original specification.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003e7800 series ventilator fit:\u003c\/strong\u003e\n    The Anesthesia 7800 and Excel 7800 share the same battery bay geometry, connector pinout, and BMS handshake protocol. One cell services both units without modification.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through the 7800's internal self-test sequence. The BMS accepted the new cell, completed its verification pass, and held charge across repeated charge-discharge cycles without fault flags.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation self-test protocol:\u003c\/strong\u003e\n    After fitting this cell, allow the ventilator to complete its full power-on self-test without interruption. The 7800's BMS runs a chemistry verification step at boot — cutting power mid-sequence locks in a false battery fault that persists until the unit is fully rebooted from cold.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the Anesthesia 7800 alarms low battery with a freshly charged replacement\u003c\/h3\u003e\n\n  \u003cp class=\"bpw-desc-p\"\u003eThe 7800's BMS compares measured cell voltage against a calibration threshold set to OEM cell chemistry. A new Ni-MH cell has not yet reached its stable resting voltage — it reads lower than a conditioned cell even at full charge. The BMS interprets this as insufficient charge and triggers the alarm. Running one complete charge-discharge-recharge cycle lets the cell reach its nominal resting voltage, typically 1.2V per cell, and the alarm clears on the next boot.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eVentilator will not power on after the replacement cell sat in storage\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eNi-MH cells self-discharge over storage time. If the replacement battery discharged below the BMS recovery threshold — around 4.0V for a 4-cell pack — the 7800 will not boot because the controller rejects cells it cannot verify. Connect the unit to mains power and leave it on charge for a minimum of 16 hours before attempting to power on from battery. This allows the charge IC to bring the cell up from a low-voltage state gradually. Once the pack reads above the BMS floor voltage, normal boot and self-test will proceed.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381508276314,"sku":"BWCS-GVM780MD-1","price":43.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381508309082,"sku":"BWCS-GVM780MD-2","price":50.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381508341850,"sku":"BWCS-GVM780MD-3","price":55.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-GVM780MD-1.webp?v=1778901305","url":"https:\/\/batteryweb.com\/products\/ge-datex-ohmeda-anesthesia-7800-ventilator-replacement-battery-48v-3600mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}