{"product_id":"given-imagion-pillcam-recorder-replacement-battery-37v-10000mah-li-ion","title":"Given Imagion BAT-0023A PillCam Recorder 3.7V Compatible Battery","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eGiven Imagion PillCam DR3 \/ DataRecorder 3.0 — 3.7V Li-ion Replacement Battery (BAT-0023A)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 3.7V, 10000mAh (37Wh) lithium-ion replacement battery for the Given Imagion PillCam Recorder. It fits the DR3 and DataRecorder 3.0 units used in capsule endoscopy procedures. OEM part numbers BAT-0023A and BAT-0023-SP both apply to this cell.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDR3 and DataRecorder 3.0 compatibility:\u003c\/strong\u003e\n    Both recorder variants share the same voltage rail, physical connector, and BMS handshake protocol. A single cell platform covers the full PillCam Recorder line without modification.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through the DR3's full charge-discharge profile and monitored BMS communication throughout. The protection circuit responded correctly to charge termination and load cutoff at expected thresholds.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation self-test cycle:\u003c\/strong\u003e\n    After fitting this battery, let the recorder complete its power-on self-test without interruption. The DR3 runs a BMS verification sequence at startup — cutting power during this window triggers a false battery fault that persists until a full reboot clears it.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the DR3 may not reach 100% charge on the first cycle with a new cell\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe DR3's charge IC applies a conservative current limit when it encounters a cell it hasn't profiled yet. On the first charge, it may terminate early — typically stopping between 95% and 98% — rather than pushing the cell to full capacity. This is normal behaviour, not a cell fault. Complete one full charge-discharge cycle and the charge IC will recalibrate its termination threshold. After that first cycle, the indicator should reach 100% consistently.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eDR3 alarm showing low battery immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe PillCam Recorder's BMS uses stored chemistry thresholds calibrated to the OEM cell's discharge curve. A new replacement cell has a slightly different internal resistance profile until it's been cycled, which causes the BMS to misread state-of-charge on first use. The low battery alarm triggers because the BMS threshold hasn't yet matched to the new cell — not because the cell is actually depleted. Run one complete charge-discharge cycle before clinical use. After that, the BMS recalibrates and the alarm clears at the correct voltage point.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381415575642,"sku":"BWCS-GDR023MD-1","price":103.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381415608410,"sku":"BWCS-GDR023MD-2","price":123.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381415641178,"sku":"BWCS-GDR023MD-3","price":137.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-GDR023MD-1.webp?v=1778900597","url":"https:\/\/batteryweb.com\/products\/given-imagion-pillcam-recorder-replacement-battery-37v-10000mah-li-ion","provider":"BatteryWeb","version":"1.0","type":"link"}