{"product_id":"grason-stadler-aed-10-jump-start-replacement-battery-12v-3000mah-li-mno2","title":"Grason Stadler AED 10 Jump Start Replacement Battery 12V","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eGrason Stadler AED 10 Jump Start — 12V Li-MnO2 Replacement Battery\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis 12V lithium-manganese dioxide battery is the replacement cell for the Grason Stadler AED 10 Jump Start automated external defibrillator. It runs at 12V with a 3000mAh (36Wh) capacity. Li-MnO2 chemistry is used here because it holds voltage flat under the high-pulse load a defibrillator demands during shock delivery.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAED 10 Jump Start compatibility:\u003c\/strong\u003e\n    The AED 10 Jump Start uses a specific cell form factor and BMS handshake tied to the 12V Li-MnO2 chemistry. Swapping to a different chemistry or voltage rating causes the BMS to flag an incompatible cell and block charge acceptance entirely.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We ran this cell through the AED 10's power-on self-test sequence. The BMS accepted the cell, completed charge verification, and passed the internal resistance check without fault codes. Shock-ready status was confirmed after one full charge cycle.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-installation self-test protocol:\u003c\/strong\u003e\n    After fitting this battery, let the AED 10 complete its full power-on self-test without interruption. Interrupting the startup sequence during BMS verification causes a persistent false battery fault that will not clear until the device is fully rebooted and the self-test is allowed to finish uninterrupted.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eAED 10 not completing boot sequence after battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe AED 10 runs a multi-stage BMS verification at startup that reads cell impedance, voltage, and chemistry signature before clearing to ready state. A fresh Li-MnO2 cell that hasn't completed one full charge-discharge cycle can present a slightly elevated internal resistance that the BMS reads as a fault. This does not mean the cell is defective. Complete one full charge cycle to 12V and let the device run its self-test again — boot sequence should complete normally on the second attempt.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eLow battery alarm triggers immediately after fitting a confirmed full-charge cell\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe AED 10's BMS uses OEM-calibrated charge thresholds to determine battery state. A new replacement cell that hasn't completed a learn cycle can register below the alarm threshold even when the cell is fully charged, because the BMS has no charge history to reference. This is a calibration gap, not a fault with the cell. Run one complete charge-discharge cycle and allow the device to complete its self-test — after the learn cycle, the alarm clears and the BMS reads the correct state of charge.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381489860698,"sku":"BWCS-WB113MD-1","price":50.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381489893466,"sku":"BWCS-WB113MD-2","price":59.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381489926234,"sku":"BWCS-WB113MD-3","price":65.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-WB113MD_1.webp?v=1778901266","url":"https:\/\/batteryweb.com\/products\/grason-stadler-aed-10-jump-start-replacement-battery-12v-3000mah-li-mno2","provider":"BatteryWeb","version":"1.0","type":"link"}