{"product_id":"hp-hewlett-packard-m2636a-replacement-battery-108v-5200mah-li-ion","title":"HP M2636A Patient Monitor Replacement Battery 10.8V 5200mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eHP M2636A \/ M2636B Patient Monitor — 10.8V Li-ion Replacement Battery\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 10.8V, 5200mAh (56.16Wh) Li-ion battery for the HP Agilent M2636A and M2636B portable patient monitors. These monitors are used in clinical and hospital settings for continuous vital signs acquisition. This battery restores portable operation when the original cell degrades below the device's BMS acceptance threshold.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eM2636A and M2636B compatibility:\u003c\/strong\u003e\n    Both models share the same 10.8V battery platform, connector pinout, and BMS handshake protocol. One battery covers both units in a mixed clinical fleet.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through the M2636 charge-discharge profile and confirmed the BMS accepted the new cell, passed the capacity verification step, and cleared the low-battery flag without manual reset.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePower-on self-test protocol:\u003c\/strong\u003e\n    After installing this battery, let the monitor complete its full startup self-test without interruption. The M2636 runs a BMS verification routine at boot — cutting power during this sequence triggers a persistent battery fault flag that will not clear until the next complete reboot cycle.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eDevice not completing boot sequence after battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe M2636 runs a BMS handshake during startup that checks cell voltage, internal resistance, and capacity state against stored thresholds. A new cell fresh from storage may sit at a resting voltage that passes the hardware check but fails the software capacity estimate. The monitor then halts the boot sequence and displays a battery error before reaching the monitoring screen. Run one full charge cycle to 10.8V before the first clinical use — this updates the BMS state-of-charge register and allows the boot sequence to complete normally.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eLow battery alarm triggering immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThis happens when the BMS's internal capacity model has not yet calibrated to the new cell's actual chemistry. The alarm threshold is evaluated against a learned capacity baseline, and on a new cell that baseline defaults to a conservative OEM reference value. The monitor reads the new cell as partially discharged even when it is physically full. One complete charge-to-discharge-to-charge cycle resets the learned baseline — after that cycle, the alarm threshold tracks correctly against the real cell capacity.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381516271706,"sku":"BWCS-ALE600SL-1","price":173.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381516304474,"sku":"BWCS-ALE600SL-2","price":205.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381516337242,"sku":"BWCS-ALE600SL-3","price":229.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-ALE600SL-1.webp?v=1778616258","url":"https:\/\/batteryweb.com\/products\/hp-hewlett-packard-m2636a-replacement-battery-108v-5200mah-li-ion","provider":"BatteryWeb","version":"1.0","type":"link"}