{"product_id":"innomed-ca360b-replacement-battery-12v-3000mah-ni-mh","title":"Innomed CA360B Replacement Battery 12V 3000mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eInnomed CA360B — 12V Ni-MH Replacement Battery (R-5702-1)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 12V, 3000mAh Ni-MH replacement battery for the Innomed CA360B defibrillator. It replaces OEM part R-5702-1. The battery powers the cardiac monitoring circuits and defibrillation delivery functions of this AED unit.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCA360B and CA360-B compatibility:\u003c\/strong\u003e\n    Both model designations use the same internal battery bay, connector pinout, and BMS handshake protocol. The R-5702-1 part number covers both. No adapter or modification needed.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through charge and load discharge on an R-5702-1-compatible test rig. The BMS accepted the cell, completed the charge verification handshake, and flagged no fault codes across three consecutive cycles.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-swap self-test procedure:\u003c\/strong\u003e\n    After installing this battery, allow the CA360B to complete its full power-on self-test without interruption. The device BMS runs a chemistry verification pass at startup — cutting power during this sequence can register a false battery fault that persists until the next clean boot cycle.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eCA360B not completing boot sequence after battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe CA360B runs a BMS initialisation sequence on every cold boot. A new Ni-MH cell hasn't yet established a charge history, so the BMS may halt the boot at the battery verification stage. This isn't a cell fault — it's the device applying a conservative threshold to an uncalibrated pack. Run one full charge cycle to completion, then power the unit on and let the self-test finish uninterrupted. After that first calibrated cycle, the boot sequence completes normally.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eCA360B self-test failure after battery replacement\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eA self-test failure immediately after swapping in a new battery typically means the BMS learn cycle hasn't completed. The device expects a charge profile that a fresh cell can only establish after one full charge-discharge pass. Connect the CA360B to its charger and run a complete, uninterrupted charge cycle before placing the device back in service. Once the BMS has logged a full cycle, re-run the self-test — the pass threshold sits at 11.5V minimum under the device's internal load check.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381443002458,"sku":"BWCS-ICD360MD-1","price":173.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381443035226,"sku":"BWCS-ICD360MD-2","price":206.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381443067994,"sku":"BWCS-ICD360MD-3","price":230.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-ICD360MD-1.webp?v=1778900837","url":"https:\/\/batteryweb.com\/products\/innomed-ca360b-replacement-battery-12v-3000mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}