{"product_id":"medicaleconet-compact-5-replacement-battery-108v-2600mah-li-ion","title":"medicalEconet Compact 5 Replacement Battery 10.8V 2600mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003emedicalEconet Compact 5 — 10.8V Li-ion Replacement Battery (10-5705)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 10.8V, 2600mAh Li-ion replacement battery for the medicalEconet Compact 5 portable medical device. It uses OEM part number 10-5705 and also cross-references BN130510-BNT, BN221024, BN220818, and 031PpTC. The Compact 5, Compact 7 (alt), and Compact XL all draw from the same battery platform and connector spec.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact 5, Compact 7 (alt), Compact XL compatibility:\u003c\/strong\u003e\n    These models share a common 10.8V three-cell Li-ion architecture, identical connector pinout, and the same BMS communication protocol — which is why one cell fits all three variants without modification.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through charge, rest, and load discharge on the Compact 5 platform. The BMS handshake cleared on first connection, the charge IC accepted the cell without error flags, and the protection circuit responded correctly to end-of-discharge cutoff at the expected voltage floor.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eFirst-use self-test cycle:\u003c\/strong\u003e\n    After installing this battery, let the device complete its full power-on self-test without interruption. The medicalEconet BMS runs a chemistry verification at startup — cutting power mid-sequence triggers a false battery fault that sticks until the next clean reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eCharge indicator stalling below 100% on a new cell\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eOn the first charge, the Compact 5's charge IC applies a conservative current ceiling to an unrecognised cell — this is normal behaviour, not a fault. The controller is measuring internal resistance against a stored OEM baseline and throttling accordingly. After one complete charge-discharge cycle, the BMS updates its cell profile and the charge IC lifts the restriction. Run one full cycle before drawing any clinical conclusions about capacity.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eDevice shutting off unexpectedly during the first ten uses\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eMedical device load profiles are more demanding than consumer electronics — the Compact 5 pulls harder during active monitoring cycles than during standby. A new cell's internal resistance is slightly elevated before the electrolyte fully wets the electrodes, which causes the BMS to trip the load cutoff at a voltage that reads higher than the true reserve. This looks like premature shutdown but resolves across the first 8–10 full cycles. Do not interrupt those cycles — let each one run to the BMS cutoff floor, then charge fully back to 12.6V before the next use.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381455650906,"sku":"BWCS-BCC500MD-1","price":40.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381455683674,"sku":"BWCS-BCC500MD-2","price":46.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381455716442,"sku":"BWCS-BCC500MD-3","price":51.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-BCC500MD-1.webp?v=1778900983","url":"https:\/\/batteryweb.com\/products\/medicaleconet-compact-5-replacement-battery-108v-2600mah-li-ion","provider":"BatteryWeb","version":"1.0","type":"link"}