{"product_id":"nihon-kohden-pvm-4000-replacement-battery-72v-6600mah-li-ion","title":"Nihon Kohden SB-470P Compatible Battery 7.2V 6600mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eNihon Kohden PVM-4000 \/ PVM-4761 — 7.2V Li-ion Replacement Battery (SB-470P)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis 7.2V, 6600mAh Li-ion battery replaces the SB-470P in the Nihon Kohden PVM-4000 and PVM-4761 patient monitors. These are bedside vital signs monitors used in hospital and clinical settings. The battery provides backup power during patient transport or mains interruptions, keeping cardiac, SpO2, and blood pressure monitoring continuous.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePVM-4000 and PVM-4761 compatibility:\u003c\/strong\u003e\n    Both monitors share the same 7.2V battery rail, SB-470P connector footprint, and BMS handshake protocol — one cell fits both platforms without modification.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through the PVM-4000 charge and discharge sequence. The BMS passed the voltage handshake at startup and held the charge IC within the monitor's accepted window across multiple cycles.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-swap self-test protocol:\u003c\/strong\u003e\n    After fitting this battery, let the monitor complete its full power-on self-test without interruption. Medical device BMS firmware runs a verification sequence at boot — cutting power during this step logs a false battery fault that persists until the next clean reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the PVM-4000 alarms low battery on a freshly charged replacement\u003c\/h3\u003e\n\n  \u003cp class=\"bpw-desc-p\"\u003eThe PVM-4000 BMS compares cell impedance against a stored OEM threshold during its self-test. A new cell that hasn't completed its first full charge-discharge cycle shows higher internal impedance than a conditioned cell — enough to trip the low-battery alarm even at full state of charge. This is not a fault with the battery. Run one complete charge cycle — charge to full, allow the monitor to discharge under normal clinical load, then recharge — before drawing conclusions about battery state. After that cycle, impedance drops and the alarm clears.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003ePVM monitor will not power on after the battery sat in storage\u003c\/h3\u003e\n\n  \u003cp class=\"bpw-desc-p\"\u003eLi-ion cells self-discharge at roughly 2–3% per month in storage. If the SB-470P replacement has been sitting long enough, the cell voltage can drop below the BMS recovery threshold — typically around 6.0V for a 7.2V nominal pack — and the monitor will not boot. Connect the battery to the monitor and plug the monitor into mains power. The charge IC will apply a low-current pre-charge trickle to recover the cell voltage above the wake threshold before switching to full charge current. Do not expect a boot during this recovery phase — wait until the charge indicator activates before attempting to power on.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381410332762,"sku":"BWCS-NKM400MD-1","price":83.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381410365530,"sku":"BWCS-NKM400MD-2","price":99.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381410398298,"sku":"BWCS-NKM400MD-3","price":110.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-NKM400MD-1.webp?v=1778900625","url":"https:\/\/batteryweb.com\/products\/nihon-kohden-pvm-4000-replacement-battery-72v-6600mah-li-ion","provider":"BatteryWeb","version":"1.0","type":"link"}