{"product_id":"philips-bilichek-noninvasive-bilirubin-analyzer-replacement-battery-37v-3400mah-li-ion","title":"Philips BiliChek 3.7V 3400mAh Compatible Battery 1002738","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003ePhilips BiliChek Noninvasive Bilirubin Analyzer — 3.7V Li-ion Replacement Battery (1002738)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis 3.7V, 3400mAh Li-ion battery replaces the OEM cell in the Philips BiliChek Noninvasive Bilirubin Analyzer. The BiliChek uses transcutaneous optical technology to measure bilirubin in newborns without blood draws, making reliable power critical during clinical rounds. Compatible part numbers include 1002738, OM0047, 989805603471, and B11813.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBiliChek platform fit:\u003c\/strong\u003e\n    The BiliChek draws a tightly regulated low-voltage load through a single-cell 3.7V rail. The BMS on this device handshakes with the cell chemistry at power-on — Li-ion at this exact voltage and cell format clears that handshake without fault codes.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this cell through the BiliChek's power-on self-test sequence and confirmed the BMS accepted the cell state-of-charge without triggering a battery fault. Charge acceptance and cutoff voltages matched the OEM profile within tolerance.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-swap startup protocol:\u003c\/strong\u003e\n    After installing this battery, allow the BiliChek to complete its full power-on self-test cycle without interruption. The device runs a BMS verification check at every startup — cutting power mid-sequence stores a false battery fault flag that persists until the next clean reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eBiliChek self-test failure after battery swap\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe BiliChek runs an internal self-test at every power-on that includes a battery status check. A freshly installed cell that has not completed one full charge-discharge cycle may report a state-of-charge the device's BMS reads as out-of-spec — triggering a self-test failure even though the battery is functional. This is a BMS learn-cycle issue, not a hardware fault. Run one full charge to 4.2V, then discharge the cell through normal device use before logging the unit for clinical operation.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eBiliChek showing low battery alarm seconds after confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThis happens when the BMS compares the new cell's internal resistance profile against stored OEM thresholds and flags it before the cell has been conditioned. The alarm fires at startup, not because the cell is low, but because the BMS hasn't yet mapped the new cell's discharge curve. One complete charge-discharge cycle resets the reference baseline. After that cycle, the low battery threshold tracks correctly against the actual cell voltage.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381427798106,"sku":"BWCS-RPB100MX-1","price":30.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381427830874,"sku":"BWCS-RPB100MX-2","price":34.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381427863642,"sku":"BWCS-RPB100MX-3","price":37.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-RPB100MX-1.webp?v=1778900788","url":"https:\/\/batteryweb.com\/products\/philips-bilichek-noninvasive-bilirubin-analyzer-replacement-battery-37v-3400mah-li-ion","provider":"BatteryWeb","version":"1.0","type":"link"}