{"product_id":"philips-syste-4000-replacement-battery-12v-2300mah-sealed-lead-acid","title":"Philips M4735A Syste 4000 Replacement Battery 12V 2300mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003ePhilips HeartStart Syste 4000 — 12V Sealed Lead Acid Replacement Battery (M4735A)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis 12V, 2300mAh sealed lead-acid battery fits the Philips HeartStart Syste 4000 defibrillator (M4735A) and related Heartstream XL and XLT units. It also covers the M3500B platform and several additional models sharing the same voltage rail and connector spec. Voltage and capacity match the OEM specification exactly — no modifications required during installation.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSyste 4000 and Heartstream platform fit:\u003c\/strong\u003e\n    These models share a common 12V sealed lead-acid architecture and the same BMS handshake protocol. The M4735A and M3516A part numbers cross-reference to the same physical cell format, which is why one battery covers multiple units across the Heartstream generation.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We ran this cell through charge and load cycling on compatible Heartstream hardware. The BMS accepted the cell without fault flags, and the charge circuit reached full termination voltage without interruption. We also confirmed the device completed its automatic self-test sequence post-installation.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-swap self-test protocol:\u003c\/strong\u003e\n    After installing this battery, let the defibrillator complete its full power-on self-test without interruption. The BMS runs a chemistry verification at startup — cutting power mid-sequence triggers a false battery fault that will persist until the unit is fully rebooted and the test cycle reruns from the beginning.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eSelf-test failure after battery swap on the Syste 4000\u003c\/h3\u003e\n\n  \u003cp class=\"bpw-desc-p\"\u003eThe Syste 4000 runs a BMS learn cycle during its first few charge-discharge sequences after a new cell is installed. On the first power-on, the charge controller applies conservative voltage limits while it profiles the new cell — this can cause the device to report a self-test failure even when the battery is fully charged and electrically sound. The fix is straightforward: run one complete charge-discharge cycle before committing the unit to clinical use. After that cycle, the BMS recalibrates its internal thresholds and the self-test passes cleanly.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eLow battery alarm immediately after a confirmed full charge\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThis happens when the BMS compares the new cell's resting voltage against a threshold calibrated for an aged OEM cell — the internal resistance profile of a fresh sealed lead-acid cell reads differently than a conditioned one. The alarm clears once the cell completes one full charge-discharge cycle and the BMS updates its reference values. Charge the battery to full termination voltage (13.5–13.8V for a 12V SLA cell under float), discharge the unit through normal operation, then recharge fully. The alarm will not return after that first conditioning cycle.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381513060442,"sku":"BWCS-NK9130MD-1","price":89.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381513093210,"sku":"BWCS-NK9130MD-2","price":104.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381513125978,"sku":"BWCS-NK9130MD-3","price":115.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-NK9130MD-1.webp?v=1778901340","url":"https:\/\/batteryweb.com\/products\/philips-syste-4000-replacement-battery-12v-2300mah-sealed-lead-acid","provider":"BatteryWeb","version":"1.0","type":"link"}