{"product_id":"respironics-2500-smart-recorder-replacement-battery-72v-800mah-ni-cd","title":"Respironics 2500 Smart Recorder 7.2V Ni-CD Replacement Battery","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eRespironics 2500 Smart Recorder — 7.2V Ni-CD Replacement Battery (6420)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 7.2V 800mAh Ni-CD replacement battery for the Respironics 2500 Smart Recorder. It fits the portable overnight sleep apnea monitor used in diagnostic sleep studies. Voltage, capacity, and connector match the original specification.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003e2500 Smart Recorder compatibility:\u003c\/strong\u003e\n    The 2500 Smart Recorder runs a fixed 7.2V Ni-CD bus. The BMS expects Ni-CD charge profiling — delta-V termination, not the voltage cutoff used for Li-ion. Swapping chemistry type causes the charger to overcharge or terminate early, so this cell matches OEM chemistry exactly.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We cycled this battery through full charge and discharge on the 2500 platform. The BMS handshake completed without fault. The recorder's charge indicator progressed normally and the self-test sequence passed at startup.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eFirst-use protocol for clinical equipment:\u003c\/strong\u003e\n    After installation, let the device complete its full power-on self-test cycle without interruption. The 2500's BMS runs a battery verification routine at startup. Cutting power during this sequence triggers a persistent battery fault flag that won't clear until the next clean boot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the 2500 Smart Recorder alarms low battery with a fully charged new cell\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eThe 2500's BMS sets its low-battery threshold against a charge profile learned from the previous cell. A new Ni-CD cell has lower initial internal voltage at rest compared to a conditioned cell, so the BMS can flag it as low even after a complete charge cycle. This is not a fault with the battery — it resolves after one full charge-discharge-recharge cycle. Run that conditioning cycle before the battery goes into clinical use, not during a study.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003e2500 Smart Recorder not powering on after the battery sat in storage\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eNi-CD cells self-discharge at roughly 10–20% per month. A battery that has sat uninstalled for several months can drop below the BMS recovery threshold — typically around 6.0V for a 7.2V Ni-CD pack — and the recorder will not boot. Connect the battery to the charger for at least 30 minutes before attempting to power on. If the charge indicator still shows no activity after 30 minutes, the cell voltage may be too low for the charger to detect; try a known-good Ni-CD charger set to 7.2V to bring the pack above the detection floor first.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381367603290,"sku":"BWCS-RPS250MD-1","price":40.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381367636058,"sku":"BWCS-RPS250MD-2","price":47.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381367668826,"sku":"BWCS-RPS250MD-3","price":52.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-RPS250MD-1.webp?v=1778900303","url":"https:\/\/batteryweb.com\/products\/respironics-2500-smart-recorder-replacement-battery-72v-800mah-ni-cd","provider":"BatteryWeb","version":"1.0","type":"link"}