{"product_id":"spacelabs-91387-patient-monitor-replacement-battery-12v-700mah-ni-mh","title":"Spacelabs 91387 Patient Monitor Replacement Battery 12V 700mAh","description":"\u003cdiv class=\"bpw-desc\"\u003e\n  \u003ch2 class=\"bpw-desc-h2\"\u003eSpacelabs 91387 Patient Monitor — 12V Ni-MH Replacement Battery (OM11163)\u003c\/h2\u003e\n\n  \u003cp class=\"bpw-desc-lead\"\u003eThis is a 12V 700mAh Ni-MH replacement battery for the Spacelabs 91387 Patient Monitor and related models including the 90387 and 90499. It slots into the same bay as the original cell and connects to the same BMS interface. Voltage and capacity match the OEM specification at 12V and 8.4Wh.\u003c\/p\u003e\n\n  \u003cul class=\"bpw-desc-bullets\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003e91387, 90387, and 90499 platform:\u003c\/strong\u003e\n    These models share the same 12V battery architecture, connector pinout, and BMS handshake protocol. A single cell revision covers the full range without modification.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003eBench tested on actual hardware:\u003c\/strong\u003e\n    We ran this cell through the 91387 power-on sequence and confirmed the BMS accepted the pack, completed self-test, and held voltage above the low-battery cutoff threshold through the full first charge cycle.\u003c\/li\u003e\n\n    \u003cli\u003e\n\u003cstrong\u003ePost-swap self-test protocol:\u003c\/strong\u003e\n    After installing this battery, let the monitor complete its full power-on self-test without interruption. The 91387 runs BMS verification at startup — cutting power during this sequence logs a false battery fault that persists until the next full reboot.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003chr class=\"bpw-desc-divider\"\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eWhy the 91387 alarms low battery immediately after a confirmed full charge\u003c\/h3\u003e\n\n  \u003cp class=\"bpw-desc-p\"\u003eThe 91387 uses a charge IC calibrated to the chemistry signature of the OEM cell. A new Ni-MH pack has a slightly different internal resistance profile on the first few cycles. The BMS reads this as a low state-of-charge and trips the alarm even when the cell is fully charged. Running one complete charge-discharge cycle recalibrates the threshold. After that single conditioning cycle, the alarm clears and does not return.\u003c\/p\u003e\n\n  \u003ch3 class=\"bpw-desc-h3\"\u003eMonitor will not power on after the replacement battery sat in storage\u003c\/h3\u003e\n  \u003cp class=\"bpw-desc-p\"\u003eNi-MH cells self-discharge during storage — typically 1–3% per day at room temperature. If the pack voltage drops below approximately 10.8V, the 91387 BMS enters a protection state and blocks normal startup. Charge the battery in the monitor for a minimum of four hours before attempting to power on. If the monitor still shows no response, place it on charge for a further two hours to allow the charge IC to recover the cell from deep discharge.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BatteryWeb","offers":[{"title":"Warranty 1 Year","offer_id":43381381365850,"sku":"BWCS-SPM903MD-1","price":53.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 2 Year","offer_id":43381381398618,"sku":"BWCS-SPM903MD-2","price":63.99,"currency_code":"USD","in_stock":true},{"title":"Warranty 3 Year","offer_id":43381381431386,"sku":"BWCS-SPM903MD-3","price":70.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/4775\/0746\/files\/BW-CS-SPM903MD-1.webp?v=1778900511","url":"https:\/\/batteryweb.com\/products\/spacelabs-91387-patient-monitor-replacement-battery-12v-700mah-ni-mh","provider":"BatteryWeb","version":"1.0","type":"link"}