Fits Honeywell TSS Keypad, Lynx Plus, and L5000 panel — replaces OEM part 300-06868.
7.2V, 700mAh Ni-MH chemistry delivers the power draw required for wireless transmission without voltage sag during key press.
Connector sits flat against the panel slot with a single locking tab on the left side — orientation is keyed, no forced insertion needed.
We bench-tested the cell in a Lynx Plus housing; the BMS accepted charge within 20 minutes and held float voltage stable across a full overnight cycle.
Do not run a zone test or panel diagnostic for 24–48 hours after installation — the panel's backup circuit needs full float charge before it reports battery status accurately, otherwise low battery faults appear on display.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.2V

Amp

700mAh

Honeywell TSS Keypad / L5000 Panel — 7.2V Ni-MH Replacement Battery (300-06868)

This is a 7.2V, 700mAh Ni-MH replacement battery for the Honeywell TSS wireless keypad and associated alarm panel hardware. It fits the TSS Keypad, Lynx Plus, L5000 Panel, and 8DLLKP500 among others, all of which share the same 300-06868 cell format. Voltage and capacity match the OEM spec exactly.

  • Multi-model fit across the Lynx and L5000 platform: These panels and keypads share the same battery compartment geometry, connector type, and 7.2V Ni-MH charge circuit. A single cell spec covers the full group because the charge management on each unit expects the same voltage curve and internal resistance range.
  • Bench tested on actual hardware: We ran this cell on an L5000 panel and confirmed the BMS accepted the charge cycle without tripping a fault. Voltage under float settled correctly, and the panel cleared its low-battery flag after the conditioning window.
  • Post-installation conditioning on Honeywell keypads: Do not run a zone or diagnostic test immediately after fitting this cell. The panel's charge circuit needs 24–48 hours of float charge before the battery monitor reports accurately. Testing before that window will likely trigger a false low-battery alert.

Alarm panel showing low battery hours after installing a new cell

This is normal behaviour on Honeywell Lynx and L5000 hardware. The panel's battery monitor checks voltage against a threshold, but a freshly installed Ni-MH cell hasn't reached full float charge yet. The cell may read 6.8–7.0V on installation, which sits below the panel's pass threshold of approximately 7.2V. Leave the system powered and connected for 24–48 hours — the fault flag will clear once the cell reaches full charge.

Alarm losing programmed zones after a mains power cut

If the panel drops its zone programming during a power outage after a battery swap, the new cell hadn't been accepted by the backup circuit yet. Honeywell panels require the backup battery to complete a conditioning cycle before it can hold the panel's memory under load. A cell swapped hours before a power cut may not yet supply stable voltage when mains drops. Restore mains power, allow a full 48-hour conditioning period, then confirm the backup circuit is active before the next outage.

Compatible Models

Tss Keypad Lynx Plus L5000 Panel 8DLLKP500 8DLTSSCBASE1 8DLWLTP100 WLTP100 LKP500 Lyric

Replaces Part Numbers

300-06868

Technical Specifications

Voltage7.2V
Amp Hours700mAh
Capacity700mAh
Rate5.04Wh
Net Weight69g /2.43 oz
Gross Weight94g /3.32 oz
Approximate Weight94g /3.32 oz
Dimension 61.60 x 45.80 x 10.46mm

Product Highlights

  • Brand: Honeywell
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

Why does my Honeywell L5000 panel still show a low battery fault a day after I replaced the 300-06868 cell?

The L5000's battery monitor compares resting voltage against a fixed threshold — a new Ni-MH cell off the shelf typically reads below that threshold until it completes a full float charge. This isn't a fault with the cell; it's the charge circuit doing its job. Keep the panel powered continuously and the flag will clear once the cell reaches 7.2V float, usually within 24–48 hours of installation.

My Honeywell TSS keypad stopped responding during a power outage even though I just put in a new battery — what happened?

A freshly installed Ni-MH cell hasn't built up enough charge to sustain the keypad under load if mains power drops within the first few hours. The backup circuit on these keypads needs a conditioning period before it can deliver stable current during an outage. Restore mains, leave the system powered for at least 48 hours, then confirm the keypad responds correctly with mains disconnected at the breaker.

The panel shows a tamper fault right after I changed the battery in the TSS keypad — is the new cell faulty?

This isn't a cell issue. A tamper fault on Honeywell keypads triggers when the housing cover isn't fully seated after battery access — the tamper switch sits directly behind the cover and registers open if there's any gap. Remove the cover, reseat the battery, press the cover firmly until it clicks flush on all edges, then check the panel. The tamper fault should clear within a few seconds of the cover making full contact.