Biocare HYLB-952 ECG-1215 Replacement Battery 14.8V 2600mAh

Up to 20% off
New arrival
Sale priceFrom $47.99 USD Regular price $59.99
Shipping calculated at checkout.
Fits Biocare ECG-1215 portable electrocardiograph; replaces OEM part number HYLB-952 directly.
Delivers 14.8V at 2600mAh capacity; powers the ECG monitor through full diagnostic sessions without mid-cycle dropout.
Connector seats vertically into the battery slot with a single locking tab; verify seating until the tab clicks firm.
We bench-tested this cell in the ECG-1215 charge circuit; BMS accepted the new chemistry without fault codes on first insertion.
After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.8V

Amp

2600mAh

Biocare ECG-1215 — 14.8V Li-ion Replacement Battery (HYLB-952)

This is a 14.8V, 2600mAh Li-ion replacement battery for the Biocare ECG-1215 portable electrocardiograph. It replaces OEM part HYLB-952. The ECG-1215 is a clinical-grade device used for 12-lead cardiac rhythm monitoring in hospital wards, clinics, and mobile diagnostic settings.

  • ECG-1215 platform fit: The ECG-1215 uses a 14.8V four-cell Li-ion pack with a BMS that checks cell group voltages and temperature at startup. This replacement matches that voltage rail and connector pinout. The BMS handshake runs on power-on, not mid-session, so the pack either clears self-test or flags a fault before the device reaches the recording screen.
  • Bench tested on actual hardware: We cycled this pack through full charge-discharge runs on the ECG-1215 platform and confirmed the BMS cleared all self-test checks without triggering a battery fault. Cell balancing completed correctly across all four groups after the first full cycle.
  • Post-swap startup protocol: After installing this battery, let the device run its full power-on self-test without pressing any buttons or cycling power. The ECG-1215 BMS runs a voltage verification sequence at boot. Interrupting that sequence logs a false battery fault that stays flagged until the next clean reboot from a fully charged state.

Why the ECG-1215 BMS flags a new battery as faulty on first boot

The ECG-1215 BMS compares each cell group voltage against a stored threshold calibrated to the OEM cell chemistry. A new replacement cell ships at a partial state of charge, and its resting voltage curve does not yet match the learned profile from the original pack. This mismatch can trigger a low-battery or battery-fault warning on the first one or two boot cycles. Running one complete charge-discharge cycle lets the BMS re-characterise the pack and update its internal thresholds. After that cycle, the fault flag clears and does not return.

Charge indicator stalling below 100% on the ECG-1215

The ECG-1215 charge IC applies a conservative taper current when it detects a new or unfamiliar cell pack — this is a built-in protection behaviour, not a fault. The charge cycle extends longer than normal on the first charge as the IC holds a lower termination threshold. Do not disconnect the charger early. Let the charge run to natural termination. After the first full charge, the IC updates its end-of-charge detection and subsequent charges complete to a full 16.8V termination voltage as expected.

Compatible Models

ECG-1215

Replaces Part Numbers

HYLB-952

Technical Specifications

Voltage14.8V
Amp Hours2600mAh
Capacity2600mAh
Rate38.48Wh
Net Weight188g /6.63 oz
Gross Weight338g /11.92 oz
Approximate Weight338g /11.92 oz
Dimension 132.20 x 37.70 x 19.70 mm

Product Highlights

  • Brand: Biocare
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The ECG-1215 is showing a low battery alarm right after I fully charged the new battery — is the replacement faulty?

The replacement is not faulty. The ECG-1215 BMS compares incoming cell voltages against thresholds set by the original OEM pack, and a new cell does not yet match that learned profile. Run one complete charge-discharge cycle — charge to full termination, allow the device to discharge through normal use, then recharge fully. After that cycle the BMS updates its reference values and the alarm clears.

The ECG-1215 will not power on at all after the replacement battery sat uninstalled for several weeks — what happened?

Li-ion cells self-discharge in storage, and the ECG-1215 BMS has a minimum recovery threshold around 12.0V per pack. If the cell voltage drops below that threshold, the BMS locks out power-on to prevent damage. Connect the device to mains power via the AC adapter and leave it on charge for at least two hours without attempting to power on. The charger will trickle-charge the pack back above the BMS recovery floor, after which normal startup resumes.

The ECG-1215 is shutting off mid-recording after I installed the new battery — this didn't happen with the old pack.

New Li-ion cells have a slightly higher internal resistance in the first ten charge cycles, which causes a larger voltage sag under the ECG-1215's active recording load. The BMS reads that sag as a low-cell-voltage condition and triggers a protective shutdown before the pack is actually depleted. This behaviour resolves as the cells condition through repeated full charge-discharge cycles. Complete five full cycles before placing the unit back into clinical use — by cycle five, internal resistance drops and the mid-recording shutoff stops occurring.