Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

COMEN CM-1200A ECG Compatible Battery 11.1V 6400mAh

Up to 19% off
New arrival
Sale priceFrom $68.99 USD Regular price $84.99
Shipping calculated at checkout.
Fits COMEN CM-1200A ECG; replaces OEM part number 0110-022-000124-00.
11.1V 6400mAh lithium-ion delivers full diagnostic runtime on cardiac monitoring and rhythm analysis exams.
Connector seats straight into the device bay with positive pin forward and mechanical locking tab engaged.
We bench-tested this cell in the CM-1200A load profile; BMS accepted the new pack after two full charge cycles.
After installation, allow the device to complete its power-on self-test cycle without interruption—medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

6400mAh

COMEN CM-1200A ECG — 11.1V Li-ion Replacement Battery (0110-022-000124-00)

This is an 11.1V 6400mAh Li-ion replacement battery for the COMEN CM-1200A portable electrocardiograph. It replaces OEM part number 0110-022-000124-00. The CM-1200A is a clinical ECG machine used for 12-lead cardiac monitoring and rhythm analysis in hospitals and outpatient settings.

  • CM-1200A platform fit: The CM-1200A uses a fixed 11.1V three-cell Li-ion pack with a BMS that handshakes with the device charge controller on startup. This replacement matches that voltage rail and connector pinout exactly, so the charge IC recognises the pack and initiates the standard charge profile without throwing a fault.
  • Bench tested on actual hardware: We cycled this pack through charge and discharge on the CM-1200A platform. The BMS passed the device self-test on the second cycle after the initial conditioning charge, and the charge controller reported a clean state-of-health flag from the third cycle onward.
  • Post-swap startup protocol: After installing this battery, let the CM-1200A complete its full power-on self-test without powering the device off mid-sequence. The BMS runs a verification routine at boot — interrupting it triggers a persistent false battery fault that will not clear until the next complete restart from a fully charged state.

Why the CM-1200A flags a battery fault on the first boot after a swap

The CM-1200A runs a BMS self-test on every cold boot to verify cell voltage balance and internal resistance against stored OEM thresholds. A brand-new cell has a slightly higher internal resistance than a conditioned cell, so it can fall outside the pass window on the first check. This is not a defect — it is the device applying a clinical-grade verification standard to an unconditioned pack. Run one full charge-to-discharge cycle before relying on the battery in a patient examination setting, and the self-test will pass consistently from that point.

Charge indicator stuck below 100% on the first charge

On the first charge cycle, the CM-1200A charge IC applies a conservative current limit when it detects a new or cold cell pack — this is intentional. The indicator can stall between 90% and 98% for an extended period before the final top-off completes. Do not unplug the device during this phase. Leave it on charge until the indicator moves to 100% or the green ready light activates, then discharge fully and recharge once more to allow the charge IC to calibrate its capacity estimate to this specific pack.

Compatible Models

CM-1200A ECG

Replaces Part Numbers

0110-022-000124-00

Technical Specifications

Voltage11.1V
Amp Hours6400mAh
Capacity6400mAh
Rate71.04Wh
Net Weight300g /10.58 oz
Gross Weight440g /15.52 oz
Approximate Weight440g /15.52 oz
Dimension 110.70 x 70.00 x 19.00mm

Product Highlights

  • Brand: COMEN
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The CM-1200A is showing a low battery warning immediately after the replacement pack charged to 100% — why?

The device BMS compares the new cell's resting voltage against a threshold calibrated for a conditioned OEM pack. A fresh cell at nominal full charge can sit a few millivolts below that threshold, triggering the alarm even though the pack is genuinely charged. Run one complete charge-discharge-recharge cycle and the resting voltage will stabilise above the alarm threshold. After that cycle, the warning clears and does not return under normal use.

The CM-1200A won't power on at all after the replacement battery was left uninstalled for several weeks — what's wrong?

Li-ion cells self-discharge in storage, and if the pack voltage dropped below approximately 9V (the CM-1200A's BMS recovery floor for an 11.1V three-cell pack), the BMS has entered deep-discharge lockout to protect the cells. Connect the device to mains power and leave it charging for at least two hours before attempting to power on — the charge IC will trickle-charge the pack back above the recovery threshold. Once the voltage clears that floor, the BMS releases the lockout and the device boots normally.

The CM-1200A is shutting off unexpectedly during a patient recording — is this the new battery or the device?

New cells deliver less stable current under the CM-1200A's load profile during the first ten cycles because the electrode surfaces have not yet fully conditioned. The device's under-voltage protection trips when voltage sags sharply under load, even if the state-of-charge reads mid-range. This behaviour reduces significantly after eight to ten full cycles as the cells reach stable impedance. Complete those conditioning cycles outside of active clinical use before deploying the battery in uninterrupted patient examinations.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.