Dopod C750 Replacement Battery 3.7V 950mAh 35H00102-00M
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Dopod C750 Replacement Battery 3.7V 950mAh 35H00102-00M - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Dopod C750 Replacement Battery 3.7V 950mAh 35H00102-00M - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
950mAh
Dopod C750 — 3.7V Li-ion Replacement Battery (35H00102-00M)
This is a 3.7V, 950mAh Li-ion cell built to fit the Dopod C750 smartphone. It replaces OEM part numbers 35H00102-00M and KII0160. The physical dimensions are 44.74 × 36.63 × 5.44mm — measure your bay before ordering if you're unsure.
- C750 platform fit: The C750 uses a compact single-cell Li-ion bay with a three-contact connector carrying charge, ground, and a thermistor line. This cell matches that pinout and the BMS voltage thresholds the charging IC expects to see on initial contact.
- Bench tested on actual hardware: We cycled this cell through charge and discharge on a C750 unit. The BMS accepted the charge handshake on first connection and the protection circuit tripped correctly at the low-voltage cutoff floor — no runaway charge events observed.
- Fuel gauge recalibration on first use: On first use after installation, run the phone down to auto-shutdown, then charge to 100% without interruption. This gives the fuel gauge IC one full reference cycle against the new cell's discharge curve before the OS starts reporting percentages.
Sudden shutdown at 20–30% on the replacement cell
This is a voltage cliff, not a capacity fault. When the modem radio or screen peaks its current draw, a new cell with an uncalibrated fuel gauge may show 25% on screen while the actual resting voltage has already dropped near the BMS cutoff floor. The protection circuit cuts power before the percentage reading catches up. One full discharge-to-shutdown, then charge-to-100% cycle forces the coulomb counter to remap its endpoints against real cell behaviour. After that cycle, the reported percentage tracks actual voltage far more closely.
Phone won't power on after sitting in storage with the replacement installed
Li-ion cells self-discharge during storage, and if the C750 sat long enough, the cell voltage may have dropped below 2.5V — the point where the BMS enters lockout to prevent deep-discharge damage. The phone will show nothing when you press the power button. Connect the original charger and leave it untouched for 20–30 minutes; most BMS circuits begin a trickle pre-charge recovery sequence once the charger is detected, bringing the cell back above the lockout threshold. If the charge LED doesn't light within 30 minutes, check the charger output — it should read 5V DC at the connector.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Dopod
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
Why does my Dopod C750 show the wrong battery percentage after fitting the new cell?
The fuel gauge IC on the C750 builds its percentage map from the old cell's discharge curve — when you swap in a new cell, that map no longer matches the actual voltage profile. The result is percentage readings that jump around or land well off where real charge sits. Run one complete cycle: drain the phone to auto-shutdown, then charge uninterrupted to 100%. That single cycle gives the coulomb counter enough data to recalibrate against the new cell.
The C750 gets noticeably warm near the battery during the first few charges — is that normal?
A new Li-ion cell typically has slightly higher internal impedance before the first few cycles break it in. The charge IC pushes the same current it always has, but higher impedance converts more of that energy to heat than an aged, broken-in cell would. The warmth should reduce after three to five full charge cycles. If the phone is hot enough to be uncomfortable to hold after cycle five, check that the back cover is seated flat — a lifted cover traps heat against the battery compartment.
My Dopod C750 powers on but cuts out the moment I open a heavy app or the screen brightness spikes — what's wrong?
This is a load-induced voltage sag on an uncalibrated cell. When the display or processor pulls peak current, the cell voltage momentarily dips below the BMS cutoff threshold, and the protection circuit kills power before the OS can log a low-battery warning. The fix is the same recalibration cycle: discharge fully to auto-shutdown, then charge to 100% in one uninterrupted session. After that, the fuel gauge IC maps the voltage sag curve correctly and the BMS cutoff no longer fires prematurely under load.