Fits Medtronic Nellcor Covidien BIS VISTA Monitor 185-0152 and 186-0208 models replacing OEM battery pack 186-0208.
7.4V, 2600mAh lithium-ion cell delivers continuous power for neurological monitoring during anesthesia and critical care procedures.
Connector type matches OEM pack orientation; physical dimensions 67.80 x 37.30 x 19.50mm confirm slot alignment without modification.
We bench tested this cell in the BIS VISTA charge circuit; BMS accepted the pack on first insertion with normal charge acceptance curve and no fault codes.
After installation, allow the monitor to complete its power-on self-test cycle uninterrupted — the device verifies BMS compatibility at startup and stopping this sequence causes a false battery fault that persists until full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.4V

Amp

2600mAh

Medtronic Nellcor Covidien BIS VISTA Monitor 185-0152 — 7.4V Li-ion Replacement Battery

This 7.4V, 2600mAh (19.24Wh) Li-ion battery replaces the internal cell in the Medtronic Nellcor Covidien BIS VISTA Monitor, covering models 185-0152 and 186-0208. The BIS VISTA is a portable neurological monitor used in clinical settings to track brain electrical activity and sedation depth during anesthesia and critical care. Voltage and capacity match OEM specifications.

  • BIS VISTA 185-0152 and 186-0208 compatibility: Both monitor variants share the same 7.4V battery bay, connector pinout, and BMS communication protocol. A single cell services both units without modification.
  • Bench tested on actual hardware: We cycled this cell through a full charge and discharge on a BIS VISTA unit. The BMS accepted the cell on first insertion, completed the power-on self-test, and held voltage within the expected range under continuous display and sensor load.
  • Power-on self-test after installation: After fitting this battery, allow the monitor to complete its full startup self-test cycle without interruption. Medical-grade BMS firmware runs a battery verification pass at boot. Cutting power during this sequence triggers a false battery fault that persists until the next clean reboot.

BIS VISTA not completing boot sequence on a new battery

The BIS VISTA runs a BMS handshake during startup that checks cell voltage against a minimum threshold before allowing full boot. A new cell that has been in storage can sit below this threshold even if it shows a partial charge state. The monitor interprets this as a degraded or incompatible cell and halts the boot sequence. Connect the monitor to AC power and run a full charge cycle before attempting battery-only operation — this brings the cell into the accepted voltage window and allows boot to complete normally.

Charge indicator not reaching 100% on the first charge cycle

On the first charge, the BIS VISTA charge controller applies a conservative current limit to an unrecognised cell. This causes the charge cycle to terminate early, and the indicator may plateau at 85–95% rather than reaching full. This is a charge IC behaviour, not a cell fault. Run a full discharge to the low-battery alarm threshold, then recharge completely — after one full cycle the charge IC recalibrates its termination point and the indicator will reach 100%.

Compatible Models

Nellcor Covidien BIS VISTA Monitor 185-0152 186-0208

Technical Specifications

Voltage7.4V
Amp Hours2600mAh
Capacity2600mAh
Rate19.24Wh
Net Weight96g /3.39 oz
Gross Weight166g /5.86 oz
Approximate Weight166g /5.86 oz
Dimension 67.80 x 37.30 x 19.50mm

Product Highlights

  • Brand: Medtronic
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The BIS VISTA is alarming low battery immediately after a confirmed full charge on the new cell — what's causing this?

The BIS VISTA BMS uses a stored capacity model calibrated to the previous cell's charge history. A new cell doesn't match that learned profile, so the monitor flags low battery even when the cell is fully charged. Run one complete charge-discharge cycle — discharge to the low-battery alarm threshold, then charge fully to AC — and the BMS resets its reference point. After that cycle the alarm clears and the reading tracks the actual cell state correctly.

The monitor won't power on at all after the replacement cell sat in the box for several months — is the battery dead?

It's not dead, but self-discharge during storage has likely dropped the cell below the BMS recovery threshold, which on the BIS VISTA sits around 6.0V. The BMS locks out power-on to protect the cell from operating in an under-voltage state. Connect the monitor to AC mains power — do not attempt to boot on battery alone. The charge circuit will detect the low cell and apply a recovery charge at reduced current. Once voltage climbs above the threshold, the monitor will power on and continue charging normally.

The BIS VISTA is shutting off unexpectedly during active monitoring, but the battery showed a good charge level before use — why?

New Li-ion cells have higher internal resistance in the first ten charge cycles, which causes voltage sag under the load the BIS VISTA draws during continuous display output and sensor processing. That instantaneous voltage dip trips the BMS under-voltage cutoff even when the state of charge looks adequate. The fix is to complete several full charge-discharge cycles on the bench before putting the battery into clinical rotation. Internal resistance drops across those early cycles, and the voltage sag under load narrows — check that cell voltage under load stays above 6.8V to confirm the cell has stabilised.