Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Otometrics Madsen AccuScreen 3.7V Compatible Battery 1800mAh

Up to 21% off
New arrival
Sale priceFrom $26.99 USD Regular price $33.99
Shipping calculated at checkout.
Fits Otometrics Madsen AccuScreen and AccuScreen TE models using OEM part numbers 8-73-02400 or 1770-9672.
3.7V, 1800mAh Li-ion cell delivers the power envelope this audiometer needs for full screening session duration.
Connector seats into the battery compartment with a single retention tab—verify orientation before closing the access door.
We bench-tested the BMS against the Madsen charge circuit; the cell accepted voltage ramp without early cutoff or fault codes.
After installation, let the device complete its power-on self-test cycle without interruption—medical devices verify battery chemistry at startup, and stopping this sequence triggers a false low-battery alarm that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

1800mAh

Otometrics Madsen AccuScreen — 3.7V Li-ion Replacement Battery (8-73-02400)

This 3.7V, 1800mAh Li-ion cell replaces the original battery in the Otometrics Madsen AccuScreen and AccuScreen TE (8-04-13900) portable audiometric screening devices. It matches the OEM voltage rail and physical footprint, including dimensions of 53.00 × 35.30 × 11.00mm. Capacity is drawn from product specification — 1800mAh / 6.66Wh.

  • AccuScreen and AccuScreen TE compatibility: Both the standard AccuScreen and the TE variant share the same battery bay geometry, connector pinout, and BMS handshake protocol. The same 3.7V cell services both units without modification.
  • Bench tested on actual hardware: We ran this cell through a full charge cycle and monitored the BMS handshake on power-up. The battery management system authenticated correctly, the charge IC accepted the cell without fault flags, and the device completed its power-on sequence normally.
  • Post-installation self-test cycle: After fitting this battery, let the AccuScreen complete its full power-on self-test without interruption. The BMS runs a verification routine at startup — cutting power during this sequence triggers a false battery fault that stays latched until the next clean reboot.

AccuScreen not completing boot sequence on a new battery

The AccuScreen runs a BMS learn cycle during its first few charge-discharge passes. On a fresh cell, the charge IC applies a conservative voltage ceiling until the BMS has profiled the new chemistry — this can cause the boot sequence to stall or produce a battery fault on the first one or two power cycles. This is not a defective cell. Run one complete charge to full termination, then discharge through normal clinical use, and repeat once. After that cycle, the BMS calibration stabilises and the boot sequence completes cleanly.

Charge indicator not reaching 100% on the first charge

On the first charge of a new Li-ion cell, the AccuScreen's charge controller applies a reduced current ceiling while it characterises the cell's internal resistance. The display may plateau at 95–99% and hold there rather than reaching full termination. This is the charge IC acting conservatively on an uncharacterised cell — not a capacity or compatibility fault. Leave the device on charge until the indicator clears to 100%; this typically completes by the second charge cycle once the controller has a baseline resistance reading for the new cell.

Compatible Models

Madsen AccuScreen AccuScreen TE 8-04-13900

Replaces Part Numbers

8-73-02400 1770-9672

Technical Specifications

Voltage3.7V
Amp Hours1800mAh
Capacity1800mAh
Rate6.66Wh
Net Weight40g /1.41 oz
Gross Weight65g /2.29 oz
Approximate Weight65g /2.29 oz
Dimension 53.00 x 35.30 x 11.00mm

Product Highlights

  • Brand: Otometrics
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The AccuScreen is alarming low battery immediately after a confirmed full charge — why?

The BMS self-test threshold is calibrated to the OEM cell's internal resistance profile. A new replacement cell has a slightly different resistance signature on the first cycle, and the BMS can misread this as a low-state-of-charge condition. Run one complete charge-discharge cycle through normal use, then recharge to full termination. After that single conditioning cycle, the BMS recalibrates its threshold against the new cell's actual profile and the false alarm clears.

The AccuScreen won't power on at all after the battery sat unused for several months — is the cell dead?

Li-ion cells self-discharge during storage. If the cell dropped below the BMS recovery threshold — typically around 2.5V — the protection circuit locks the cell out as a safety measure and the device will not respond to the power button. Place the AccuScreen on charge and leave it connected for a minimum of 30–60 minutes before attempting to power on; most charge ICs apply a low-current recovery charge below 3.0V before switching to normal CC/CV charging. If the charge indicator shows activity within that window, the cell is recovering — allow it to reach full termination before booting the device.

The AccuScreen is shutting off unexpectedly during a hearing test, but the battery shows adequate charge beforehand — what's causing this?

New Li-ion cells carry slightly elevated internal resistance in the first 10 charge-discharge cycles. The AccuScreen's clinical load profile — particularly the signal generation and display during active testing — draws enough current that voltage sag across that resistance briefly dips below the BMS low-voltage cutoff, triggering a protective shutdown even when the state of charge reads fine at rest. This resolves as internal resistance drops through normal cycling. Complete at least 5–8 full charge-discharge cycles before relying on this battery for uninterrupted clinical sessions.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.