Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Schiller ARGUS VCM 8.4V Replacement Battery 110657-O

Up to 18% off
New arrival
Sale priceFrom $116.99 USD Regular price $140.99
Shipping calculated at checkout.
Fits Schiller ARGUS VCM and ARGUS VCM Vital Sign Monitor; replaces OEM part numbers 110657-O and M6021-1.
8.4V 7600mAh Ni-MH pack delivers sustained output for full patient assessment cycles without mid-procedure shutdowns.
Connector slides straight into the battery bay with a positive-lock tab that seats flush against the housing frame.
We bench-tested the cell at full discharge load; the BMS accepted the new pack after one complete charge cycle without fault codes.
After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

8.4V

Amp

7600mAh

Schiller ARGUS VCM — 8.4V Ni-MH Replacement Battery (110657-O)

This 8.4V 7600mAh Ni-MH battery replaces the OEM pack in the Schiller ARGUS VCM and ARGUS VCM Vital Sign Monitor. These are portable cardiac monitoring and defibrillation units used in emergency and critical care environments. Voltage and capacity match the original specification: 8.4V, 7600mAh (63.84Wh).

  • ARGUS VCM platform fit: Both listed ARGUS VCM variants run the same voltage rail, connector pinout, and BMS handshake protocol — one battery pack covers both. Cross-reference OEM part numbers 110657-O and M6021-1 before ordering to confirm your unit's original pack.
  • Bench tested on actual hardware: We cycled this pack through charge and discharge on the ARGUS VCM platform. The BMS completed its initialisation sequence, accepted the cell chemistry without a fault flag, and held voltage within the device's accepted operating window across load cycles.
  • Post-installation self-test protocol: After fitting this battery, allow the ARGUS VCM to complete its full power-on self-test without interruption. The device runs a BMS verification routine at startup. Interrupting that sequence before it finishes can log a false battery fault that persists until the next complete reboot.

Why the ARGUS VCM flags a battery fault after the first charge cycle

The ARGUS VCM's charge IC applies a conservative upper limit when it encounters a new Ni-MH cell. The BMS tracks charge acceptance against a learned baseline built from the previous pack. A fresh cell has no baseline, so the monitor can log a fault or refuse to clear the low-battery indicator even after a confirmed full charge. One complete charge-to-discharge-to-full-recharge cycle resets the learned threshold and clears the flag. Do not place the device in clinical rotation until that cycle is complete.

ARGUS VCM powering off mid-use on a recently charged battery

Unexpected shutdown during patient monitoring is usually a voltage sag event, not a capacity failure. New Ni-MH cells have higher internal resistance in the first ten cycles, and the ARGUS VCM's load profile during defibrillation charging stresses the pack harder than standby draw. If the cell voltage drops below the BMS cutoff threshold under that load, the device shuts off as a protection event. Run three to five full charge-discharge cycles before clinical use — internal resistance drops significantly by cycle five, and voltage sag under peak load stabilises above the 6.0V BMS cutoff floor.

Compatible Models

ARGUS VCM ARGUS VCM Vital Sign Monitor

Replaces Part Numbers

110657-O M6021-1

Technical Specifications

Voltage8.4V
Amp Hours7600mAh
Capacity7600mAh
Rate63.84Wh
Net Weight734.2g /25.90 oz
Gross Weight804.2g /28.37 oz
Approximate Weight804.2g /28.37 oz
Dimension 85.00 x 68.50 x 46.80mm

Product Highlights

  • Brand: Schiller
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The ARGUS VCM is showing a low battery alarm straight after I charged the replacement — is the battery faulty?

It is not faulty. The ARGUS VCM's BMS compares charge acceptance against a baseline built from the previous pack. A new cell has no stored baseline, so the monitor interprets it as underperforming and triggers the alarm even on a full charge. Run one complete charge-to-discharge-to-full-recharge cycle before concluding there is a fault. The alarm clears once the BMS has a full cycle of data to calibrate against.

The ARGUS VCM won't power on after the replacement battery sat unused for several weeks — how do I recover it?

Extended storage causes Ni-MH cells to self-discharge, and if the pack voltage drops low enough, the device's BMS will not initiate a boot sequence. Place the battery on a standalone Ni-MH charger first and bring it up to a safe recovery voltage before reinstalling. Once reinstalled, allow the ARGUS VCM to complete its full power-on self-test without interruption. If the device still does not boot after a confirmed full charge, check cell voltage directly — recovery is unlikely below 5.0V across the pack.

The charge indicator on the ARGUS VCM hasn't reached 100% after several hours on a new replacement battery — is the charger the problem?

The charger is most likely not the problem. The ARGUS VCM's charge IC applies a reduced current limit when it first encounters a new Ni-MH cell, which extends the time to a full charge indication compared with a conditioned pack. This is normal behaviour on cycle one. Let the charge run to completion without interrupting it — pulling the pack early locks the BMS into a partial-charge state that can take multiple cycles to correct. After the first full charge, subsequent cycles will reach 100% within the device's standard charge window.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.