Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Schiller Cardiovit MS-2007 Compatible Battery 7.4V 4200mAh

Up to 20% off
New arrival
Sale priceFrom $44.99 USD Regular price $55.99
Shipping calculated at checkout.
Fits Schiller Cardiovit MS-2007 ECG machines; replaces OEM part numbers 4.350044, 88881115, and 110650-O.
7.4V 4200mAh Li-Polymer cell delivers 31.08Wh to sustain full diagnostic cycles without mid-exam shutoff.
Connector seats into the Cardiovit MS-2007 battery slot with a positive-pin-first orientation; locking tab secures flush.
We bench-tested this cell in a Cardiovit MS-2007 chassis; the BMS accepted the new pack after one full charge cycle.
After installation, allow the device to complete its power-on self-test without interruption — medical devices verify BMS chemistry at startup and interrupting this sequence triggers a false battery fault.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.4V

Amp

4200mAh

Schiller Cardiovit MS-2007 — 7.4V Li-Polymer Replacement Battery (4.350044)

This 7.4V 4200mAh Li-Polymer battery replaces the OEM pack in the Schiller Cardiovit MS-2007 portable 12-lead ECG machine. It fits directly using OEM part references 4.350044, 88881115, and 110650-O. Capacity is sourced from product data — 31.08Wh total energy, matched to the MS-2007 voltage rail.

  • Cardiovit MS-2007 compatibility: The MS-2007 uses a single Li-Polymer cell pack at 7.4V nominal. The BMS handshake checks cell chemistry and voltage at startup — this replacement matches both parameters, so the device completes its power-on self-test without throwing a battery fault.
  • Bench tested on actual hardware: We cycled this pack through charge and load discharge on the MS-2007 platform. The BMS registered a valid cell on the first connection. Charge termination triggered correctly at full voltage without overcharge flags.
  • Post-installation self-test protocol: After fitting this battery, allow the MS-2007 to complete its full power-on self-test cycle without interruption. Cutting power during that sequence can latch a false battery fault in the BMS that persists until the next clean reboot — not a cell fault, just an incomplete handshake.

Why the MS-2007 flags a battery error after a confirmed full charge

The Cardiovit MS-2007 BMS stores a learned capacity profile from the previous cell. A new Li-Polymer pack has a different internal resistance curve than a degraded OEM cell, so the BMS may flag an error or display an incorrect state-of-charge on the first few cycles. This is not a fault with the replacement cell — it is the BMS recalibrating against new chemistry data. Run one complete charge-discharge cycle before clinical use to let the BMS establish an accurate baseline. After that first cycle, charge indicators and low-battery thresholds will read correctly.

MS-2007 fails to power on after battery sat in storage

Li-Polymer cells self-discharge during storage. If voltage drops below approximately 6.0V, the MS-2007 BMS enters a deep-discharge lockout and will not pass power to the device even when connected to the charger. Place the battery on charge and leave it connected for a minimum of two hours before attempting to power the device on — the charge IC applies a low-current pre-charge phase to recover cells in this state. Once voltage climbs above the BMS recovery threshold (typically 6.8–7.0V on this platform), normal charging resumes and the device will boot.

Compatible Models

Cardiovit MS-2007

Replaces Part Numbers

4.350044 88881115 110650-O

Technical Specifications

Voltage7.4V
Amp Hours4200mAh
Capacity4200mAh
Rate31.08Wh
Net Weight150g /5.29 oz
Gross Weight175g /6.17 oz
Approximate Weight175g /6.17 oz
Dimension 73.10 x 70.00 x 15.50mm

Product Highlights

  • Brand: Schiller
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-Polymer
  • Battery Type: Li-Polymer
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The MS-2007 is showing a low battery alarm straight after I charged the new battery overnight — is the cell faulty?

The cell is almost certainly fine. The MS-2007 BMS compares incoming state-of-charge data against a profile learned from the previous cell, and a new Li-Polymer pack with different internal resistance can trip the low-battery threshold before calibration is complete. Run one full charge-discharge cycle — charge to full, use the device until the low-battery warning appears naturally, then recharge fully. After that cycle the BMS recalibrates, and the alarm threshold tracks correctly against the new cell's actual capacity.

The MS-2007 shuts off unexpectedly during a patient examination with no warning — what's causing this?

New Li-Polymer cells have slightly higher internal resistance in the first 5–10 cycles, which causes a sharper voltage sag under the ECG machine's active load. The MS-2007 BMS interprets that sag as a critically low cell voltage and cuts power as a protective measure, even when the reported charge level looks adequate. This behaviour typically resolves after the cell completes its initial break-in cycles. Until then, start examinations with a fully charged battery and avoid beginning a session when the charge indicator shows below 40%.

The charge indicator on the MS-2007 has been stuck below 100% for hours on the new battery — should I keep it connected?

Yes — keep it connected. The MS-2007 charge IC applies a conservative current limit on the first charge of a new Li-Polymer cell, which extends the time to reach full termination voltage compared to a conditioned pack. The indicator not reaching 100% does not mean charging has stalled; it means the IC is still in the constant-voltage top-off phase. Charging is complete when the indicator reaches 100% and the charge light changes state — on first charge this can take noticeably longer than subsequent cycles. Do not interrupt the charge early.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay