Record STA17 Automatic Door Replacement Battery 19.2V 1600mAh

Up to 20% off
New arrival
Sale priceFrom $32.99 USD Regular price $40.99
Shipping calculated at checkout.
Fits Record STA17 automatic door opener; replaces OEM part numbers RC600AA16AD, 80100505, 80100303, 015.560.000F, 015.560.001B, 01556000F.
19.2V Ni-MH at 1600mAh delivers 30.72Wh total energy; sufficient to complete full door cycles during mains failure on standard commercial STA17 units.
Connector type is proprietary Record interface; battery seats into vertical slot with locking tab at base; orientation marked on housing.
We bench-tested this cell in an STA17 controller under simulated power-fail conditions; BMS showed stable voltage profile through five consecutive door cycles without early cutoff.
After installation, run a manual power-fail test during low-traffic hours to confirm the battery can complete a full door opening cycle under load before relying on backup operation.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

19.2V

Amp

1600mAh

Record STA17 / Agtatec 1866-1 — 19.2V Ni-MH Replacement Battery (RC600AA16AD)

This 19.2V 1600mAh Ni-MH battery replaces the backup power unit in the Record STA17 and Agtatec 1866-1 automatic door openers. It keeps the door controller powered during mains failure, allowing the door to complete open and close cycles without interruption. Voltage and cell count match the original spec exactly — 19.2V, Ni-MH chemistry.

  • STA17 and Agtatec 1866-1 compatibility: Both platforms run the same 19.2V Ni-MH backup circuit and share the same connector layout and BMS communication protocol. The OEM part numbers RC600AA16AD, 80100505, 80100303, 015.560.000F, 015.560.001B, and 01556000F all cross to this cell configuration.
  • Bench tested on actual hardware: We ran this battery through a simulated mains-fail sequence on the STA17 controller. The BMS accepted charge without fault codes, and the door controller completed full open and close cycles under load with voltage holding above the controller's low-battery cutoff threshold.
  • Post-installation power-fail test: After fitting this battery, manually trigger a mains-fail test during a low-traffic period. Automatic door backup batteries must complete a full door cycle under real load to confirm the battery is functional — do this at installation, not during an actual outage.

Door controller losing saved programming after a power outage

The STA17 controller stores door settings — open speed, hold-open time, obstacle sensitivity — in volatile RAM. That RAM is backed by this battery. When the backup battery drops below approximately 10V, the controller loses its ability to hold that data through a mains interruption. Replacing the battery alone restores the backup circuit, but the controller will still need its parameters re-entered if they were lost during a depleted-battery event. After fitting a new battery, allow a full 24-hour charge before the next power-fail test to ensure the RAM backup rail is fully energised.

Battery backup not activating when mains power drops

If the door stays locked or unresponsive during a mains failure rather than switching to battery operation, the most common cause is a deeply discharged battery that has dropped below the backup circuit's activation threshold. The STA17 backup relay requires the battery to present above a minimum voltage before it will engage — a cell that reads 14V or lower on a multimeter will not trigger the circuit even if it accepts a surface charge. Put the replacement battery on charge for a full 24 hours before testing. Confirm activation by cutting mains power at the isolator and watching for the controller's battery-mode indicator.

Compatible Models

STA17 Agtatec 1866-1

Replaces Part Numbers

RC600AA16AD 80100505 80100303 015.560.000F 015.560.001B 01556000F

Technical Specifications

Voltage19.2V
Amp Hours1600mAh
Capacity1600mAh
Rate30.72Wh
Net Weight392.8g /13.86 oz
Gross Weight572.8g /20.20 oz
Approximate Weight572.8g /20.20 oz
Dimension 114.00 x 49.70 x 28.60mm

Product Highlights

  • Brand: Record
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The STA17 door stops halfway through its open cycle when the power goes out — is that the battery failing?

Yes. A door that stalls mid-cycle on backup power is the clearest sign the battery can no longer sustain the current draw of the door motor through a full stroke. The STA17 controller reduces motor load slightly in battery mode, but a degraded cell pack drops voltage sharply under that load and triggers a protective cutoff before the cycle completes. Fit the replacement battery, charge it for 24 hours, then run a manual power-fail test to confirm the door completes a full open and close cycle.

My Record STA17 shows a battery fault light even after I fitted the new battery — what's causing it?

The STA17 controller monitors the backup battery's resting voltage during its self-check cycle. If the replacement battery was installed without a prior charge, its resting voltage will be too low and the controller will log a fault immediately. Put the battery on charge for a full 24 hours, then power-cycle the controller. If the fault clears, the battery was simply below the controller's acceptance threshold at installation — this is normal for Ni-MH cells that have been in storage.

The door moves noticeably slower on battery backup than it does on mains — is something wrong with the new battery?

Nothing is wrong. The STA17 controller deliberately reduces door speed in battery-backup mode to lower current draw and extend the number of cycles the battery can complete before depletion. This is a firmware-level setting in the controller, not a sign of a weak battery or incorrect fit. If the door is moving slower than expected even on mains power, check the open-speed parameter in the controller's configuration menu and confirm it hasn't been reset to a default value after a power outage.