Beghelli 415391001 Emergency Light Replacement Battery 7.2V 1500mAh
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Beghelli 415391001 Emergency Light Replacement Battery 7.2V 1500mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Beghelli 415391001 Emergency Light Replacement Battery 7.2V 1500mAh - is backordered and will ship as soon as it is back in stock.
Voltage
7.2V
Amp
1500mAh
Beghelli 415391001 — 7.2V Ni-MH Replacement Battery (98100095)
This is a 7.2V, 1500mAh Ni-MH replacement battery for the Beghelli 415391001 emergency lighting unit. It restores backup power to the fitting so exit routes stay illuminated during a mains failure. Capacity matches the original cell at 10.8Wh.
- 415391001 fitting compatibility: The Beghelli 415391001 uses a dedicated charge controller calibrated to the float voltage and charge acceptance curve of a 7.2V Ni-MH pack. Swapping to a different chemistry or voltage causes the controller to misread cell state and either undercharge or refuse to charge altogether.
- Bench tested on actual hardware: We ran the cell through a full charge cycle and applied a load consistent with emergency lamp draw. The BMS accepted charge without fault and the cell voltage held within expected range across the discharge curve.
- First-installation test cycle: Within 24 hours of fitting the new cell, hold the test button for the full rated duration. This allows the charge controller to register the new cell's capacity before any scheduled compliance test — a fresh Ni-MH cell from storage may not be at full charge on arrival.
Charge indicator staying red after new battery installation
Beghelli emergency fittings use a float-charge controller that checks incoming cell voltage before switching to a green charge status. A Ni-MH cell shipped from storage can sit at 6.8V or lower, which falls outside the controller's acceptance window. The controller interprets this as a fault rather than a discharged cell. Leave the fitting on mains power for 12–24 hours — once the cell climbs above approximately 7.0V, the controller registers it and the indicator should move off red.
Emergency light dims partway through a duration test
This happens when the replacement cell has not completed a full conditioning cycle before the test is run. A new Ni-MH cell reaches rated capacity only after at least one full charge-discharge cycle. During a duration test, a partially conditioned cell hits its lower voltage threshold early and the lamp output drops. Run one full manual test cycle — charge for 24 hours, then hold the test button for the complete rated period — before logging the result for any compliance record.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Beghelli
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The fitting passed its duration test before I replaced the battery, but now it fails — what changed?
A new Ni-MH cell does not deliver full rated capacity on its first discharge straight from storage. The Beghelli charge controller needs at least one complete charge-discharge cycle before the cell reaches 1500mAh. Charge the fitting on mains for 24 hours, then run a full manual test by holding the test button for the complete rated duration. Log the compliance result only after that first conditioning cycle.
The fault LED is still lit after I've confirmed the new battery is seated and connected correctly — why won't it clear?
Some Beghelli fittings latch a fault LED in firmware and do not reset it automatically when a new cell is detected. The fix is a manual reset: isolate the fitting from mains, wait 30 seconds, then restore power. If the LED still shows fault after the fitting has charged for one hour, check that the cell connector is fully engaged — a partial connection reads as an open circuit to the controller.
The old battery looked swollen when I removed it — is that a sign of a deeper problem with the fitting?
Swelling in a Ni-MH pack is overcharge damage, almost always caused by years of continuous trickle charge inside a fitting running at elevated temperature. Check that the fitting's charge termination circuit is functioning — a failed termination circuit applies trickle current indefinitely instead of dropping to float level. With the new cell installed and the fitting on mains, measure voltage at the battery terminals after 24 hours; it should read between 7.2V and 7.56V. A reading above 7.8V points to a faulty charge controller that will damage the replacement cell in the same way.