Chloride ELU10500B200 High Performance Replacement Battery
Couldn't load pickup availability
⚠️ Quick Reminder
    🔹 Please ensure the original battery model number is listed in our product description and that your device model number matches for compatibility.
   🔹  We only supply the batteries shown in the images. Device images are provided for reference only.
  
📸 Send Your Battery Photo / Unsure? Expert Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR IMAGE
                    
                      
Battery Care Guide
                      
                    
                  
                  Battery Care Guide
Battery Usage and Maintenance Guidelines 🔋
Please read the following instructions carefully before using your new battery. Proper adherence will help ensure optimal performance and extended service life.
1. Cordless Phones, PDAs, and Power Tools (NiMH, NiCd, Lithium-Ion) 📱
Initial Charge
- Fully charge the battery overnight prior to first use.
 
Conditioning (First 2–6 Charge Cycles)
- Operate the device until the battery reaches approximately 20% capacity.
 - Avoid premature recharging.
 - Do not allow the battery to fully discharge during the initial cycles.
 
Post-Conditioning
- Recharge the battery only when necessary.
 - These batteries are capable of approximately 500 charge cycles:
 -   Once daily → ~500 days
Twice daily → ~250 days
Note: Even a partial recharge is considered a full cycle. 
2. Sealed Lead Acid (SLA) Batteries 💡
- No conditioning required.
 - Maintain the battery in a fully charged state; avoid complete discharge.
 - Capable of 300–400 charge cycles.
 - Expected service life: 2–3 years, depending on usage conditions.
 
3. Laptop Batteries (Lithium-Ion) 💻
Initial Charge
- Fully charge the battery overnight prior to first use.
 
Conditioning (First 2–6 Charge Cycles)
- Charge fully, then discharge to approximately 20% capacity.
 - Avoid complete discharge, as some devices may not detect a fully drained battery.
 
Post-Conditioning
- Minimize frequent plugging and unplugging.
 - Allow the battery to discharge moderately at least once per month to maintain optimal performance.
 - Occasional cycling is recommended to sustain battery health.
 
Professional Recommendation
Adhering to these guidelines will enhance battery longevity and ensure reliable performance.
For further assistance regarding your battery or order, our customer support team is available to provide guidance.
                    
                      
Delivery and Shipping
                      
                    
                  
                  Delivery and Shipping
⚡ Everything You Need to Know About Shipping with BatteryWeb (USA)
We know reliable delivery matters when you need power fast. Here’s how BatteryWeb makes shipping easy across the USA:
🚚 Shipping & Delivery
Most orders ship next business day (some products like sealed lead acid may take a little longer).
Same-day shipping available if you order before 11:59 AM (delivery depends on the carrier).
We ship nationwide using FedEx, UPS, USPS, DHL, and regional ground carriers.
Shipping costs are calculated automatically at checkout based on weight, distance, and carrier.
Transit times shown are estimates only (business days, no weekends/holidays).
🌍 Shipping Restrictions
Lithium batteries cannot be shipped by USPS or air. They must go via FedEx Ground, UPS Ground, or DHL Ground.
PO Box deliveries are only available via USPS.
At this time, we do not ship lithium batteries to Puerto Rico. NiMH, NiCd, and Alkaline can be shipped.
📦 Important Notes
Double-check your shipping address! If an incorrect address is used and the order is returned, re-shipping costs are the buyer’s responsibility.
If a product is temporarily out of stock, we’ll notify you right away with the expected restock date—or issue a refund if you prefer.
💲 Currency & Pricing
All prices are shown in USD.
Orders shipped outside the USA may be subject to local taxes, customs fees, or import duties. These are the buyer’s responsibility.
⚡ At BatteryWeb, we’re committed to getting your batteries delivered quickly, safely, and affordably—so you’ll always have the power you need, when you need it.
                    
                      
Disclaimer
                      
                    
                  
                  Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
🔹 Our products are generic replacement parts and are not affiliated with, endorsed by, or manufactured by the original equipment manufacturers (OEMs).
Volts & Amps
6 Volts | 36 Ah
Terminal Type
F2
Chloride ELU10500B200 Replacement Battery — Compatible with Chloride ELU10500B200
Ensure continuous protection with the Chloride ELU10500B200 replacement battery. Built to meet or exceed OEM SLA battery standards, this high-performance battery provides maintenance-free, long-lasting power ideal for emergency lighting and other standby systems. The Chloride ELU10500B200 long-lasting battery delivers reliable compatibility and professional-grade performance to keep critical systems operational.
Key Specifications
- Model Compatibility: Chloride ELU10500B200
 - Technology: Absorbent Glass Mat (AGM) Technology
 - Design: Maintenance-Free
 - Construction: Spill Proof
 - Certifications: U.L. Recognized and CE Certified
 - Condition: Brand New, Factory Fresh
 - Warranty: 1 Year Warranty
 - Brand: SigmasTek
 - Voltage: 6 Volts
 - Capacity: 36 Ah
 - Terminal Type: F2
 - Meets/Exceeds: OEM SLA battery specifications
 
Benefits
With AGM technology and a spill-proof, maintenance-free construction, this replacement battery delivers robust durability and dependable long-term performance. The design reduces upkeep and allows safe installation in confined or vertical spaces. As a high-performance battery, it offers steady output and efficient recharge behavior—key for emergency lighting and standby power needs.
Certified by U.L. and CE, the Chloride ELU10500B200 replacement battery is appropriate for regulated environments and commercial installations. It is commonly used for emergency lighting, security and fire alarm systems, medical equipment, consumer electronics, and home & garden applications. Additionally, the battery is suitable for uninterruptible power supplies (UPS), emergency power backups, and portable tools that require reliable SLA replacement batteries.
Shipped brand new and backed by a one-year warranty, the SigmasTek Chloride ELU10500B200 replacement battery gives you OEM-level compatibility and the assurance of a quality, long-lasting power solution.
Take action now—purchase the Chloride ELU10500B200 replacement battery to secure dependable, high-performance power for your critical systems.
- 
                      Voltage
 - 
                      Amp Hours
 - 
                      Terminal Type
 - 
                      Length (in.)
 - 
                      Width (in.)
 - 
                      Height (in.)
 - 
                      Weight (lb.)
 - 
                      Warranty
 - 
                      Type
 - 
                      Manufacturer
 - 
                      Brand Replacement
 
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
            
      
      
      