Bard Medsystems Harvard Syringe Pump 3.6V Replacement Battery
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Bard Medsystems Harvard Syringe Pump 3.6V Replacement Battery - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Bard Medsystems Harvard Syringe Pump 3.6V Replacement Battery - is backordered and will ship as soon as it is back in stock.
Voltage
3.6V
Amp
5000mAh
Bard Medsystems Harvard Syringe Pump — 3.6V Ni-CD Replacement Battery (10930)
This 3.6V, 5000mAh Ni-CD battery is a direct replacement for the Bard Medsystems Harvard Syringe Pump. OEM part numbers covered include 10930, 6029, B11229, and HV-9250-003. The Harvard Syringe Pump is a clinical infusion device used in hospital and healthcare settings to deliver precise intravenous medication doses.
- Harvard Syringe Pump platform fit: These OEM part numbers share the same 3.6V Ni-CD cell configuration, connector type, and BMS handshake protocol. Any of the four cross-reference numbers will match this pack without wiring modification.
- Bench tested on actual hardware: We cycled this cell through full charge and load discharge on the Harvard Syringe Pump platform. The BMS accepted the new pack and passed internal resistance verification without flagging a chemistry mismatch.
- Post-installation self-test requirement: After fitting this battery, allow the pump to complete its full power-on self-test without interruption. The device runs a BMS verification routine at startup — cutting power mid-sequence stores a false battery fault that will persist until the next clean reboot.
Low battery alarm triggering immediately after a confirmed full charge
Ni-CD cells from storage have not yet completed a full charge-discharge learn cycle, so the pump's BMS applies a conservative internal resistance threshold that a new cell rarely meets on first charge. The device reads this as a below-minimum state and triggers the alarm even though the cell is fully charged. Run one complete charge-to-cutoff, then a full discharge under device load, and the BMS recalibrates its threshold. After that cycle, the alarm clears and the pump reports charge state accurately.
Harvard Syringe Pump failing to boot after the battery sat in storage
Ni-CD cells self-discharge at roughly 15–20% per month in storage. If a replacement pack has been sitting long enough, the cell voltage drops below the BMS recovery threshold — typically around 3.0V — and the pump will not initiate its boot sequence. Connect the battery to the charger before installing it in the device and allow a full charge cycle to complete. Once the cell climbs above the recovery threshold, the pump will boot and run its self-test normally.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Bard Medsystems
- Manufacturer: CS
- Series: Standard
- Color: Green
- Product Type: Ni-CD
- Battery Type: Ni-CD
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The pump passed self-test fine but shuts off unexpectedly mid-infusion — why is a new battery doing this?
New Ni-CD cells have not yet formed their internal structure fully, so internal resistance is higher in the first 10 cycles than it will be at steady state. Under the sustained load profile of an active infusion, that resistance causes a sharper voltage sag than the BMS expects, and it trips the low-voltage cutoff as a protective measure. This is not a faulty cell — it normalises after several full charge-discharge cycles as the Ni-CD plates condition. Complete at least one full cycle off the device before returning the pump to active clinical use.
The charge indicator on the Harvard Syringe Pump never reaches 100% on the first charge of a new battery — is the cell defective?
It is not defective. The pump's charge IC applies a conservative termination current limit on cells it has not yet profiled. On a new Ni-CD pack, that limit causes the charge cycle to terminate early before the indicator reaches full. Run the battery down under normal device load, then charge it fully a second time — the charge IC updates its termination model and the indicator will reach 100% correctly from that point forward.
After swapping the battery, the pump completed boot but the self-test threw a battery fault code — how do we clear it?
The BMS runs a capacity verification step during self-test and compares it against a stored baseline from the previous cell. A fresh Ni-CD pack with no cycle history does not have a matching baseline, so the BMS logs a fault. Power the pump off completely, allow it to sit unpowered for 60 seconds, then restart it cleanly. The BMS discards the previous baseline and re-runs verification against the new cell — confirm the self-test completes without interruption and the fault code will not recur.