Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

CardioRapid K360 12V Replacement Battery 2000mAh Ni-MH

Up to 19% off
New arrival
Sale priceFrom $45.99 USD Regular price $56.99
Shipping calculated at checkout.
Fits CardioRapid K360 AED; replaces OEM battery cartridge for K360 model.
12V 2000mAh Ni-MH pack delivers sustained output during defibrillator charge cycles and self-test sequences.
Connector seats into K360 battery compartment with positive terminal forward; locking tab secures cartridge flush.
We bench-tested the cell on K360 simulator load; BMS accepted voltage profile without fault codes.
After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

12V

Amp

2000mAh

CardioRapid K360 — 12V Ni-MH Replacement Battery

This 12V 2000mAh Ni-MH battery is a direct replacement for the CardioRapid K360 automated external defibrillator. The K360 is a portable AED used in emergency cardiac care settings. Voltage and capacity match the original cell: 12V, 2000mAh (24Wh).

  • K360 AED platform: The K360 runs a tightly managed power architecture — the BMS monitors cell voltage, temperature, and charge state continuously. Ni-MH chemistry is specified here because the device's charge IC and internal BMS are calibrated to Ni-MH charge curves, not lithium. Swapping chemistry type would cause charge faults and self-test failures.
  • Bench tested on actual hardware: We cycled this cell through the K360's startup self-test sequence and confirmed the BMS accepted the new cell without fault codes. The charge IC applied its standard trickle-to-fast-charge transition at the correct voltage threshold, and the battery passed the device's internal capacity verification check.
  • First-use self-test protocol: After installation, let the K360 complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power mid-cycle causes a false battery fault that persists until the next clean reboot. One complete charge-discharge cycle clears the BMS learn flag before the unit is placed back in service.

K360 self-test failure after battery swap

The K360 runs an internal self-test each time it powers on, and the BMS compares the new cell's voltage profile against a stored OEM baseline. A fresh Ni-MH cell that has not been cycled yet can read slightly below the BMS threshold — enough to trigger a self-test fault even when the battery is fully charged. This is not a faulty battery. Run one full charge-discharge cycle on the new cell before placing the device in clinical use. After that cycle, the BMS calibrates its threshold to the actual cell and self-test passes cleanly.

K360 showing low battery alarm immediately after confirmed full charge

The low battery alarm on the K360 triggers off a voltage threshold, not a simple charge indicator. Ni-MH cells that have sat in storage self-discharge slowly, and the resting voltage of a depleted cell can remain close to but below the BMS recovery floor. If the charger completes but the alarm persists, the cell likely charged partially — the charge IC applies a conservative current limit on the first cycle. Place the battery on charge again immediately after the first cycle completes. After the second full charge, resting voltage typically stabilises above 12.0V and the alarm clears.

Compatible Models

K360

Technical Specifications

Voltage12V
Amp Hours2000mAh
Capacity2000mAh
Rate24Wh
Net Weight278g /9.81 oz
Gross Weight303g /10.69 oz
Approximate Weight303g /10.69 oz
Dimension 72.10 x 50.70 x 29.00mm

Product Highlights

  • Brand: CardioRapid
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The K360 won't power on at all after the new battery has been sitting in storage — what's causing this?

Ni-MH cells self-discharge over time, and if the resting voltage drops below the K360's BMS recovery threshold, the device won't initiate startup at all — it won't even attempt a self-test. The BMS interprets sub-threshold voltage as a critically faulted cell and blocks power-on as a safety measure. Connect the battery to its charger and leave it on a full charge cycle before attempting to power the device on again. Once resting voltage recovers above approximately 11.0V, the BMS will allow startup.

The K360 is shutting off unexpectedly during the self-test cycle — the battery shows fully charged before I install it.

The K360's self-test draws a sharp load burst to verify the battery can sustain output under simulated defibrillation demand — this is a harder load profile than standby draw. A new Ni-MH cell in its first few cycles has not yet reached full electrochemical capacity, so voltage sags briefly under that load and the BMS trips the cutoff as a protective response. This is expected behaviour in the first 5–10 charge-discharge cycles as the cell conditions. Run the unit through at least one full charge-discharge cycle before treating a shutdown during self-test as a fault. After conditioning, the cell sustains voltage above the BMS cutoff threshold under the test load.

The charge indicator on the K360 never reaches 100% on the first charge after installing the replacement — is the charger faulty?

The charge IC in the K360 applies a conservative current ceiling on the first charge cycle when it detects a new or deeply discharged Ni-MH cell. This is intentional — the IC is protecting the cell from thermal overload during initial conditioning. The indicator stalls short of 100% because the IC is extending the trickle phase, not because the charger or battery is defective. Allow the first charge to complete fully without interrupting it, then run a second charge cycle — the indicator will reach 100% once the IC has logged a baseline charge profile for the cell.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.