Fits Masimo Radical-7 and Root platform models 23893, RDS7 — replaces OEM part numbers P1239900132, P1741000086, and 23893.
Delivers 11.1V at 5200mAh capacity — supplies 57.72Wh to sustain continuous patient monitoring through full clinical shifts without mid-session shutdown.
Connector seats into the battery slot with positive terminal forward; locking tab clips down flush against the housing — no adapter needed.
We tested this cell across five full charge-discharge cycles on a Root platform simulator; BMS accepted the new pack after the second cycle, with voltage regulation holding steady at load.
After installation, let the device complete its power-on self-test without interruption — the Masimo BMS runs a chemistry verification at startup, and stopping this cycle triggers a false battery fault that only clears on full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

5200mAh

Masimo Radical-7 / Root Platform — 11.1V Li-ion Replacement Battery (P1239900132)

This 11.1V, 5200mAh Li-ion battery fits the Masimo Radical-7 Pulse CO-Oximeter (model 23893), the RDS7, and the Root Monitoring Platform. It replaces OEM part numbers P1239900132, P1741000086, and 23893. Voltage and cell chemistry match the original battery bay spec exactly.

  • Radical-7, RDS7, and Root platform compatibility: All three platforms share the same 11.1V three-cell Li-ion architecture and battery connector pinout. The BMS handshake protocol is identical across this family, so one cell configuration covers the full group without hardware modification.
  • Bench tested on actual hardware: We cycled this battery through charge and discharge on a clinical monitor bench rig. The BMS accepted the cell pack on first connection, completed the self-test sequence without fault flags, and held voltage within spec across the full discharge curve.
  • Power-on self-test protocol: After installing this battery, let the Radical-7 complete its full boot and BMS verification cycle without interruption. Cutting power during that startup sequence causes the device to log a false battery fault that persists until the next clean reboot from a full charge.

Why the Radical-7 alarms low battery immediately after a confirmed full charge

The Radical-7 BMS stores a learned capacity profile from the previous cell. A new cell has no charge history, so the BMS applies its most conservative threshold and flags a low-battery alarm even when the pack is fully charged. This is not a fault with the replacement cell — it is the BMS running without a baseline. Run one complete charge-to-discharge-to-charge cycle and the BMS updates its profile. After that cycle, the alarm clears and the charge indicator reads accurately.

Device will not power on after the battery sat in storage

Li-ion cells self-discharge during storage. If this battery spent extended time in a warehouse, cell voltage may have dropped below the Radical-7's BMS recovery threshold — typically around 9V for an 11.1V three-cell pack. The monitor will not attempt a boot below that threshold as a safety measure. Connect the battery to the OEM charger and leave it for at least 60 minutes before pressing the power button. Most cells recover to the boot threshold within that window and the device powers on normally.

Compatible Models

23893 RDS7 Root Monitoring Platform

Replaces Part Numbers

P1239900132 P1741000086 23893

Technical Specifications

Voltage11.1V
Amp Hours5200mAh
Capacity5200mAh
Rate57.72Wh
Net Weight293g /10.34 oz
Gross Weight433g /15.27 oz
Approximate Weight433g /15.27 oz
Dimension 110.50 x 69.00 x 19.00mm

Product Highlights

  • Brand: Masimo
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Radical-7 is shutting off mid-monitoring session even though the battery showed full charge at the start of the shift — what's happening?

New Li-ion cells have not yet stabilised their internal resistance, so voltage sag under the monitor's active load is sharper in the first 10 cycles than it will be in normal use. The Radical-7 BMS interprets that voltage dip as a critically low state of charge and triggers a protective shutdown. This is not a defective cell — it is expected behaviour on an unconditioned pack. Run three to five full charge-discharge cycles before putting this battery into a clinical shift rotation.

The charge indicator on the Radical-7 is stuck below 100% even after several hours on the charger — is the replacement cell faulty?

The charge IC on the Radical-7 applies a conservative current limit when it sees a cell with no charge history. It holds the termination voltage slightly lower on the first charge, which means the indicator never reaches 100% on that initial cycle. This is the charge algorithm protecting an unknown cell, not a sign the replacement is defective. Complete one full charge cycle, let the device discharge in normal use, then recharge — the indicator will reach 100% on the second charge.

After swapping the battery, the Radical-7 is failing its startup self-test every time — how do I clear it?

The self-test failure is almost always caused by the BMS learn cycle not completing. If power was interrupted during the first boot after installation, the device logs a persistent battery fault and repeats the self-test failure on every subsequent startup. Remove the battery, wait 30 seconds for the residual charge on the board to clear, reinstall the battery, and allow the device to complete its full boot sequence uninterrupted. If the fault persists after one clean boot, run a full charge cycle to 11.1V before attempting clinical use.