Fits BLU Studio 5.0K, D530K, D531K smartphones; replaces OEM part C746043210T or C746043230T.
3.7V at 1800mAh capacity delivers the original discharge curve for calls, messaging, and apps on this device.
Connector seats vertically into the battery slot; locking tab on left side clips when fully inserted and seated.
We bench-tested this cell on a D531K unit — BMS accepted the charge cycle without delay, voltage held steady through discharge.
On first use after installation, run one complete discharge-charge cycle without fast charging enabled to let the fuel gauge IC recalibrate against this cell's discharge curve before high-current charging resumes.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

1800mAh

BLU Studio 5.0K / D530K / D531K — 3.7V Li-ion Replacement Battery (C746043210T)

This 3.7V, 1800mAh Li-ion cell replaces the original battery in the BLU Studio 5.0K, D530K, and D531K smartphones. It matches OEM dimensions at 74.15 × 60.00 × 4.08mm, so it seats correctly in the battery bay without modification. Capacity is 6.66Wh — identical to factory spec.

  • Studio 5.0K / D530K / D531K compatibility: All three models share the same battery bay geometry, connector pin-out, and BMS handshake protocol. One cell covers all three variants without adapter or re-wiring.
  • Bench tested on actual hardware: We cycled this cell through full charge and discharge on the D531K. The BMS accepted the charge handshake on the first connection, and protection circuitry tripped correctly at both high-current draw and low-voltage floor.
  • Fuel gauge recalibration on first cycle: On first use after installation, disable fast charging and run one complete discharge-to-charge cycle. This gives the fuel gauge IC a clean reference curve against the new cell before high-current charging begins on an uncalibrated coulomb counter.

Sudden shutdown at 20–30% on the Studio 5.0K after a cell swap

A fresh Li-ion cell has a steeper voltage discharge curve than a worn original. The fuel gauge IC on the Studio 5.0K was calibrated to the old cell's curve, so it misreads remaining capacity on the new cell. When the modem fires up for a call or the screen brightness spikes, current draw pulls the cell voltage below the BMS cutoff threshold — even though the OS still shows 20–30%. One full discharge-to-charge cycle lets the coulomb counter reset its internal model against the actual cell curve. After that cycle, shutdowns at falsely reported percentages stop.

Phone feels warm near the battery during the first few charges

A new Li-ion cell typically has higher internal impedance than a broken-in cell. The charge IC pushes current into higher resistance, generating more heat until the cell completes its first few formation cycles. This is normal for the first two to three charges and resolves as impedance drops. If the phone stays warm beyond the third full charge, check that no background process is keeping the screen and modem active simultaneously during charging — those two loads together can keep the charge IC working harder than it needs to.

Compatible Models

Studio 5.0K D530K D531K

Replaces Part Numbers

C746043210T C746043230T

Technical Specifications

Voltage3.7V
Amp Hours1800mAh
Capacity1800mAh
Rate6.66Wh
Net Weight39g /1.38 oz
Gross Weight64g /2.26 oz
Approximate Weight64g /2.26 oz
Dimension 74.15 x 60.00 x 4.08mm

Product Highlights

  • Brand: BLU
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My BLU Studio 5.0K shuts off randomly at around 25% battery — why does this happen with a new cell?

The fuel gauge IC on the Studio 5.0K was calibrated to the discharge curve of the original cell. A new cell has a different voltage slope, so the OS misreports remaining capacity. Under sudden load — a call connecting, screen brightness spiking — the cell voltage drops below the BMS cutoff while the gauge still reads 25%. Run one full uninterrupted discharge down to automatic shutdown, then charge to 100% without interruption. That single cycle re-anchors the coulomb counter to the new cell's actual curve.

The Studio 5.0K shows a jumping or erratic battery percentage after I installed the replacement cell — is the battery defective?

It is not defective. The fuel gauge IC is actively recalibrating against a cell it has never seen before. Until it completes at least one full discharge-charge reference cycle, percentage readings will skip or bounce, particularly between 40% and 80% where the voltage curve is flattest. Let the phone discharge fully to auto-shutdown, then charge uninterrupted to 100%. Erratic readings typically stabilise within one to two cycles after that.

The Studio 5.0K won't power on after the replacement battery sat in storage — how do I recover it?

If the cell discharged below approximately 2.5V during storage, the BMS enters a lockout state to prevent damage from charging a deeply depleted cell. Plug the phone into a wall charger — not a computer USB port — and leave it connected for at least 20–30 minutes without pressing the power button. The charge IC will trickle current into the cell until voltage rises above the BMS re-enable threshold, at which point the phone will boot normally. If the charging indicator does not appear after 45 minutes on a wall charger, the cell may have dropped below recoverable voltage.