Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Fukuda FL-1B ECG Replacement Battery 3.7V 1800mAh

Up to 20% off
New arrival
Sale priceFrom $33.99 USD Regular price $41.99
Shipping calculated at checkout.
Fits Fukuda EK-168G, EK-268G, EK-468G portable ECG systems; replaces OEM FL-1B battery pack.
3.7V lithium-ion cell rated 1800mAh powers sustained cardiac monitoring sessions without mid-measurement dropout.
Connector slides into vertical slot with spring-loaded retention tab; polarity marked on housing.
We bench-tested this pack through full discharge cycles on the EK-168G platform — BMS held steady output under sustained sensor load with no premature cutoff events.
After installation, run the device's full self-test calibration sequence before field deployment; the ECG instrument maps battery voltage during calibration and skipping this step triggers false low-battery warnings on your first measurement.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

1800mAh

Fukuda EK-168G / EK-268G / EK-468G — 3.7V Li-ion Replacement Battery (FL-1B)

The FL-1B is a 3.7V Li-ion cell rated at 1800mAh (6.66Wh) for the Fukuda EK-168G, EK-268G, and EK-468G portable electrocardiograph units. These are clinical-grade ECG devices used in ward rounds, field cardiac surveys, and outpatient settings. This replacement restores power when the original cell no longer holds a usable charge.

  • EK-168G / EK-268G / EK-468G platform fit: All three models share the same battery bay geometry, connector pinout, and BMS handshake protocol — the FL-1B spans the full series without modification.
  • Bench tested on actual hardware: We ran the pack through full charge cycles and confirmed the BMS negotiates correctly with the ECG unit's charge controller — no false low-battery flags, no mid-trace shutdowns under lead load.
  • Post-install calibration on the EK series: After fitting a new cell, run the unit through one complete recording session before clinical use. The EK series maps battery state during active operation, and skipping this step causes the on-screen charge indicator to misreport capacity on the first patient session.

BMS lockout after the EK-168G sat unused in a carry case for months

Li-ion cells in portable ECG units self-discharge slowly during storage. If the pack drops below approximately 2.5V, the BMS trips a protection latch and the unit appears completely dead — not just flat. The charger sees a near-zero voltage cell and refuses to initiate a charge cycle. Connecting the unit to its OEM charger for 20–30 minutes at low current is usually enough to bring the cell above the 2.9V recovery threshold and unlock the BMS. If the indicator light never changes state after that window, the original cell has reached end of life and requires this replacement.

ECG trace resets or freezes mid-recording during a multi-lead session

When the EK series powers all twelve leads simultaneously, the combined current draw spikes well above standby load. An aged or marginal cell voltage sags under that draw, crossing the BMS undervoltage threshold even though the display showed adequate charge beforehand. The BMS cuts output to protect the cell, the unit resets, and the trace is lost. This is not a firmware fault — it is a cell capacity problem. Fit a fresh FL-1B and verify the terminal voltage reads at or above 3.7V before the next recording session.

Compatible Models

EK-168G EK-268G EK-468G

Replaces Part Numbers

FL-1B

Technical Specifications

Voltage3.7V
Amp Hours1800mAh
Capacity1800mAh
Rate6.66Wh
Net Weight36g /1.27 oz
Gross Weight61g /2.15 oz
Approximate Weight61g /2.15 oz
Dimension 53.80 x 33.90 x 10.20mm

Product Highlights

  • Brand: Fukuda
  • Manufacturer: CS
  • Series: X-Longer
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The EK-168G powers on fine but shuts off the moment I start a full 12-lead recording — why?

Activating all twelve leads at once pulls a short current spike that a degraded cell cannot sustain without its voltage dropping below the BMS cutoff threshold. The unit powers on normally at rest because standby draw is low, but collapses under the combined sensor load. This is a cell capacity failure, not an instrument fault. Fit a new FL-1B and confirm the open-circuit voltage reads 3.7V or above before attempting the next recording.

The EK-168G won't charge at all after sitting in storage for several months — is the charger the problem?

Almost certainly not the charger. After extended storage, the cell voltage can fall below 2.5V, which trips the BMS protection latch. The charger detects a near-zero voltage pack and refuses to start a charge cycle as a safety measure. Connect the unit to the OEM charger and leave it for 20–30 minutes — if the cell recovers above 2.9V the BMS will re-initialise and normal charging resumes. If the charge indicator never changes state after that window, the original cell is unrecoverable and needs replacing with the FL-1B.

My EK-268G shows a full battery on screen but the low-battery warning triggers within minutes of starting a trace — what's happening?

The EK series derives its charge indicator from voltage thresholds mapped during active use, not a static percentage counter. When a new cell is fitted — or after deep discharge and recovery — those thresholds haven't been recalibrated to the new cell's actual discharge curve yet. The display reads full at rest but the warning trips early once load pulls the voltage down into the old threshold range. Run one complete recording session to let the unit remap its voltage-to-indicator relationship, and the warnings will align correctly from the next session onward.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.