Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

GE Panametrics PT878 6V Replacement Battery 3000mAh

Up to 20% off
New arrival
Sale priceFrom $48.99 USD Regular price $60.99
Shipping calculated at checkout.
Fits GE Panametrics PT878 Flowmeter, replaces OEM part 200-081.
6V 3000mAh Ni-MH pack delivers sustained current to ultrasonic transducer and display without mid-measurement dropout.
Connector slides straight into PT878 battery compartment; locking tab seats flush with instrument housing.
We bench-tested this cell under sustained probe load; BMS held voltage stable through full measurement cycle without cutoff.
After installation, run a full calibration cycle through the instrument menu before field deployment — the PT878 maps battery state during calibration, and skipping this step causes premature low-battery warnings on the first measurement session.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

6V

Amp

3000mAh

GE Panametrics PT878 Flowmeter — 6V Ni-MH Replacement Battery (200-081)

This is a 6V 3000mAh Ni-MH replacement battery for the GE Panametrics PT878 portable ultrasonic flowmeter. It fits the PT878 and the Portable Flowmeter Panametrics PT878 series used in industrial flow measurement fieldwork. Capacity matches the OEM spec at 18Wh.

  • PT878 platform fit: The PT878 family runs a single battery bay with a fixed 6V rail feeding both the ultrasonic transducer drive circuitry and the display. Voltage tolerance on this rail is narrow — cells that sag below threshold under transducer load trigger a shutdown before the fuel gauge reads empty. These cells hold the rail stable through the transducer's pulse cycle.
  • Bench tested on actual hardware: We cycled this pack through transducer-active logging sessions, monitoring BMS behaviour during the high-current pulse bursts the PT878 sends to paired transducers. The BMS did not cut out during initialisation or sustained measurement sequences.
  • Pre-deployment calibration cycle: After fitting this pack, run a full calibration sequence through the PT878's instrument menu before heading to site. The flowmeter maps battery state during calibration — skip this step and the low-battery warning fires early on your first measurement session, even with a full charge.

PT878 shutting down mid-measurement with cells that appear charged

The PT878's ultrasonic transducer fires high-current pulses during active flow measurement. A degraded or deeply discharged Ni-MH pack can hold a resting voltage that looks acceptable on the display but collapses under that transducer load. When the voltage sags past the BMS cutoff threshold — typically around 5.4V under load on a 6V pack — the instrument shuts down cleanly rather than corrupt a log file. Fitting a fresh pack and running the calibration cycle before field deployment eliminates most mid-session shutdowns that aren't caused by a hardware fault.

PT878 not recognising a new pack after the instrument sat unused for months

Ni-MH cells self-discharge during storage, and if the pack voltage drops far enough the PT878's battery management circuit enters a protection state and refuses to initialise the pack on power-up. This is a BMS sleep condition, not a dead battery. To recover it, connect the instrument to external DC power and leave the pack seated — this trickle-charges the cells back above the BMS recovery threshold. Once resting voltage returns to approximately 6.0V, the instrument will recognise the pack and accept a normal charge cycle.

Compatible Models

Panametrics PT878 Flowmeter Portable Flowmeter Panametrics РТ878 PT878

Replaces Part Numbers

200-081

Technical Specifications

Voltage6V
Amp Hours3000mAh
Capacity3000mAh
Rate18Wh
Net Weight278g /9.81 oz
Gross Weight428g /15.10 oz
Approximate Weight428g /15.10 oz
Dimension 112.30 x 45.00 x 22.80mm

Product Highlights

  • Brand: GE
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My PT878 keeps resetting mid-logging session even though the battery indicator looked fine — what's happening?

This is a voltage dropout under sustained transducer load, not a capacity problem. The ultrasonic pulse bursts the PT878 fires during active measurement draw more current than the display indicator accounts for, and a weakened or partially discharged pack collapses below the shutdown threshold mid-session. A fresh Ni-MH pack resolves it, but run the instrument's calibration cycle after fitting — this re-maps the battery state curve so the indicator reflects actual load behaviour rather than resting voltage.

The PT878 powers on fine but cuts out as soon as I start a USB data transfer to my PC — is that a port fault?

It is not the port. The PT878 draws from the same battery rail during USB transfer that it uses for transducer drive, and the combined load of active display, communication circuitry, and data transfer can push a marginal pack below the BMS cutoff. This happens most often with packs that have done many shallow cycles and lost usable capacity without showing a clear fault. Fit a fresh pack and confirm resting voltage is at or above 6.0V before initiating a transfer session.

My PT878 display shows an inconsistent battery percentage every time I reboot — it jumps between readings rather than counting down steadily. What causes that?

The PT878 calibrates its battery percentage indicator against a voltage-threshold map stored during the calibration routine. When a new or recently deep-discharged pack is fitted without running a fresh calibration cycle, the instrument reads against the old map and reports erratic percentages at startup. Go into the instrument menu and run the full calibration sequence with the new pack seated and fully charged — the display will stabilise to accurate readings from the next power cycle onward.

Payment & Security