Qolsys IQ Panel 2 Replacement Battery 7.2V 2000mAh Ni-MH
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Qolsys IQ Panel 2 Replacement Battery 7.2V 2000mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Qolsys IQ Panel 2 Replacement Battery 7.2V 2000mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Voltage
7.2V
Amp
2000mAh
Direct Sensor ds415 / 17-145A — 7.2V Ni-MH Replacement Battery
This 7.2V 2000mAh Ni-MH cell replaces the backup battery in the Direct Sensor ds415 and 17-145A security panel. It maintains alarm, siren, and communication functions when mains power drops. Capacity and voltage match the original factory specification exactly.
- Sensor ds415 and 17-145A compatibility: Both models share the same 7.2V battery rail, connector pinout, and BMS charge profile — a single cell covers either panel without modification.
- Bench tested on actual hardware: We cycled this cell through the panel's float charge circuit and confirmed the BMS accepted the cell cleanly, held the correct charge threshold, and did not trigger a false low-battery fault after the 48-hour conditioning window.
- Post-installation zone testing: Do not run a zone or siren test immediately after swapping this cell. The panel charge controller needs 24–48 hours at float before the BMS reports accurate state-of-charge — triggering a test before that window closes will return a false low-battery warning.
Alarm panel losing programming during a power outage with a new battery fitted
A freshly installed Ni-MH cell starts well below its rated 7.2V and cannot sustain the panel's logic board through a mains dropout until the battery has been conditioned. The panel draws a stabilised voltage of approximately 6.8–7.2V to hold memory and zone configuration — anything below that threshold causes a reset. If a power cut occurs within the first 48 hours of fitting, the battery may drop below that rail before the panel can save state. Install the cell and leave it on mains float charge for a full 48 hours before the backup circuit is relied upon.
Panel still showing low battery 24 hours after a new cell was installed
The Sensor ds415 BMS samples battery voltage periodically and compares it against a stored low-battery threshold — it does not immediately re-evaluate when a new cell is fitted. If the panel flagged a low-battery fault on the old cell, that fault status can persist until the new cell reaches full float charge and the BMS runs its next scheduled check cycle. This typically clears between 24 and 48 hours after installation. If the warning remains past 48 hours, check that the panel is connected to a live mains supply and that the battery connector is fully seated — a partial connection will hold the cell at a false low voltage reading.
Compatible Models
Technical Specifications
Product Highlights
- Brand: Direct
- Manufacturer: CS
- Series: Standard
- Color: Blue
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The siren didn't sound during our weekly test right after we replaced the battery — is the new cell faulty?
The cell is almost certainly fine. The ds415 panel imposes a short charge-stabilisation delay on the siren output when a new battery is first accepted — this prevents a partial cell from driving the siren and then cutting out mid-alert. Wait 30–60 minutes after installation before running a siren test; if it still fails to sound after that window, confirm the cell voltage at the connector reads at least 6.8V with a multimeter.
Our panel lost all its zone programming during a power cut two days after we swapped the battery — why?
A new Ni-MH cell needs 48 hours of continuous float charge before it can sustain the panel's logic board through a mains outage. Below approximately 6.8V the panel cannot hold memory, so zones and settings reset. If the power cut happened inside that 48-hour window, the cell simply wasn't conditioned yet. Restore mains power, re-enter the zone programming, and allow the full 48-hour conditioning period before the backup circuit is relied upon again.
The panel is showing a tamper fault we've never seen before — we only opened it to change the battery
A tamper fault on the ds415 almost always means the panel lid or housing cover is not fully closed after a battery swap. The tamper circuit is triggered by a small contact switch on the enclosure — if the cover is even slightly ajar, the panel reads it as a tamper breach. Open the enclosure, reseat the battery connector, close the cover firmly until it clicks, and then check the panel display; the tamper fault should clear within a few seconds.
Payment & Security