Fits Bionet BM7Vet Optional patient monitor; replaces OEM part HS111202-BNT and SCR18650-F22-032PTCW battery cells.
10.8V, 6800mAh lithium-ion pack delivers 73.44Wh for extended monitoring sessions without mid-procedure power loss.
Connector seats into the vertical battery slot on the monitor's rear panel with a positive-terminal-up orientation and quarter-turn locking tab.
We bench-tested this cell in the BM7Vet platform; BMS initialized correctly on first insertion and passed full-charge verification without cutoff or fault codes.
After installation, allow the device to complete its power-on self-test cycle uninterrupted — the monitor's BMS runs verification at startup, and stopping this sequence triggers a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

10.8V

Amp

6800mAh

Bionet BM7Vet Optional — 10.8V Li-ion Replacement Battery (HS111202-BNT)

This 10.8V, 6800mAh Li-ion battery replaces the original power cell in the Bionet BM7Vet Optional portable veterinary patient monitor. It fits the BM7Vet Optional directly and matches OEM part numbers HS111202-BNT and SCR18650-F22-032PTCW. Capacity is rated at 73.44Wh, consistent with the original specification.

  • BM7Vet Optional platform fit: The BM7Vet Optional uses a fixed 10.8V three-cell Li-ion configuration with a BMS that validates cell voltage and internal resistance at startup. This replacement matches that configuration — voltage rail, connector pinout, and BMS communication protocol align with the original pack.
  • Bench tested on actual hardware: We cycled this cell through charge, standby, and load conditions representative of continuous patient monitoring. The BMS passed the startup handshake and held voltage within spec under sustained draw. No false fault codes were triggered after the first full charge cycle.
  • Startup self-test protocol: After installing this battery, let the BM7Vet Optional complete its full power-on self-test without interruption. The device runs a BMS verification sequence at boot — cutting power mid-sequence generates a battery fault flag that persists until the next clean reboot, not until the next charge.

BM7Vet Optional not completing boot sequence on a new battery

The BM7Vet Optional runs a BMS verification check during the boot sequence that compares cell voltage and internal resistance against OEM baseline thresholds. A fresh replacement cell that has not completed its first full charge-discharge cycle may present resistance values outside the expected window, causing the device to stall mid-boot. This is not a hardware fault — it is a calibration gap between a new cell and the device's learned parameters. Run one full charge from flat to 100% before placing the unit into clinical use, and the boot sequence will complete normally on subsequent power-ons.

Low battery alarm triggers immediately after a confirmed full charge

The BM7Vet Optional's low-battery alarm threshold is calibrated to the internal resistance profile of a conditioned OEM cell. A new replacement cell has slightly elevated internal resistance before the first cycle is complete, which the charge IC reads as insufficient capacity even when the cell is at full voltage — typically 12.6V at the pack terminals. The alarm clears after the battery completes one full discharge and recharge cycle, allowing the BMS to update its state-of-charge model. Discharge the unit normally under monitoring load, charge fully to 12.6V, then recheck the alarm status before returning the device to service.

Compatible Models

BM7Vet Optional

Replaces Part Numbers

HS111202-BNT SCR18650-F22-032PTCW

Technical Specifications

Voltage10.8V
Amp Hours6800mAh
Capacity6800mAh
Rate73.44Wh
Net Weight295.2g /10.41 oz
Gross Weight365.2g /12.88 oz
Approximate Weight365.2g /12.88 oz
Dimension 67.20 x 58.00 x 37.50mm

Product Highlights

  • Brand: Bionet
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The BM7Vet Optional shuts off unexpectedly during a procedure — is the new battery causing this?

Yes, this is a known behaviour in the first 10 cycles on a new cell. Medical monitor load profiles stress new Li-ion cells harder than standby use, and the BMS will trip a protective cutoff if the cell voltage sags below the low-voltage threshold under sustained monitoring load before the cells have conditioned. Run three to five full charge-discharge cycles away from clinical use to allow the cells to reach stable internal resistance. After conditioning, check that the pack voltage holds above 10.0V under load before returning the unit to patient monitoring.

The BM7Vet Optional won't power on at all after the replacement battery sat in storage for several months — what happened?

Li-ion cells self-discharge during storage, and if the pack voltage drops below approximately 9.0V the BM7Vet Optional's BMS enters a deep-discharge lockout state and refuses to initiate a boot sequence. Connect the unit to mains power and leave it on charge for a minimum of four hours before attempting to power on — the charge IC applies a low-current recovery charge to bring the cell voltage back above the BMS recovery threshold before switching to full charge rate. If the unit still does not power on after four hours on charge, check that the mains adapter is supplying the correct voltage at the connector before swapping anything else.

The charge indicator on the BM7Vet Optional won't reach 100% on the first charge of the new battery — is the cell faulty?

The charge IC in the BM7Vet Optional applies a conservative upper current limit on cells it has not yet characterised, which means the first charge cycle often terminates at 95–98% state of charge rather than 100%. This is the charge controller protecting an unrecognised cell, not a defective pack. Allow the battery to complete a full discharge under normal monitoring load, then put it back on charge — the charge IC updates its cell model after the first full cycle and the indicator will reach 100% on the second charge. Verify the pack reaches 12.6V at the terminals on the second charge to confirm normal operation.