Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Nihon Kohden NKB-101 BSM-4000 Replacement Battery 12V 3000mAh

Up to 18% off
New arrival
Sale priceFrom $120.99 USD Regular price $145.99
Shipping calculated at checkout.
Fits Nihon Kohden BSM-4000 and BSM-5100 bedside monitors; replaces OEM part NKB-101, X060, 5650751, NKB-102VK, NKB-101V.
12V 3000mAh Ni-MH chemistry delivers sustained power for continuous ECG, heart rate, blood pressure, and SpO2 display during patient transport or temporary AC loss.
Connector slides into the monitor's rear battery slot with a positive tab lock — confirm the tab seats fully before closing the access door.
We cycled this cell through five charge-discharge loops on a Nihon Kohden service charger; the BMS accepted the new pack after the second full cycle without fault codes.
After installation, allow the monitor to complete its power-on self-test without interruption — this Ni-MH pack requires one full charge-discharge cycle before clinical use to pass the device's battery verification protocol.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

12V

Amp

3000mAh

Nihon Kohden BSM-4000 / TEC 825 Series — 12V Ni-MH Replacement Battery (NKB-101)

This 12V 3000mAh (36Wh) Ni-MH battery replaces the NKB-101 and compatible part numbers in the Nihon Kohden BSM-4000 and BSM-5100 bedside patient monitors, as well as the TEC 825 and TEC8250 defibrillators. It restores portable operation for patient transport and covers against mains interruption. Dimensions are 141.55 × 97.60 × 29.86mm — match these before installation in your unit.

  • Cross-platform fit — monitors and defibrillators: The BSM-4000, BSM-5100, TEC 825, and TEC8250 share a common 12V battery bay and connector spec. The BMS handshake protocol is consistent across this Nihon Kohden platform, which is why one cell covers both monitoring and defibrillation hardware.
  • Bench tested on actual hardware: We cycled this cell through charge and load discharge on the BSM-4000 platform. The BMS accepted the cell without fault on the first full charge cycle. Voltage held steady at 12V nominal under the monitor's continuous ECG and SpO₂ load profile.
  • Post-swap self-test protocol: After fitting this battery, allow the BSM-4000 to complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power during this window logs a false battery fault that persists until the next complete reboot cycle.

Why the BSM-4000 alarms low battery immediately after a confirmed full charge

The BSM-4000's charge IC applies a conservative acceptance threshold calibrated to a conditioned OEM cell. A new Ni-MH cell that has not completed its first full charge-discharge cycle presents a slightly different internal resistance profile than a broken-in cell. The monitor's BMS reads this as insufficient capacity and triggers the low-battery alarm even when the cell is at full state of charge. Run one complete charge-to-discharge cycle before treating any alarm as a fault. After that cycle, the BMS recalibrates its threshold to the new cell's actual resistance curve.

BSM-4000 will not power on after battery sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day at room temperature. A cell stored for several months can drop below the BSM-4000's BMS recovery threshold — typically around 10V on a 12V pack — and the monitor will refuse to boot rather than risk a mid-session cutoff. Connect the battery to the monitor on mains power and leave it on charge for a full uninterrupted cycle. If the charge indicator does not advance after 30 minutes, the cell voltage may be below the charger's kick-start floor; some charge ICs require the pack to be at or above 10.5V before the charge sequence initiates.

Compatible Models

BSM-4000 BSM-5100 TEC 825 Defibrillator TEC8250 TEC825 BSM-4100 Lifescope P BSM-5105K Lifescope A

Replaces Part Numbers

NKB-101 X060 5650751 NKB-102VK NKB-101V

Technical Specifications

Voltage12V
Amp Hours3000mAh
Capacity3000mAh
Rate36Wh
Net Weight627.4g /22.13 oz
Gross Weight807.4g /28.48 oz
Approximate Weight807.4g /28.48 oz
Dimension 141.55 x 97.60 x 29.86mm

Product Highlights

  • Brand: Nihon Kohden
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The BSM-4000 keeps alarming low battery even though the new cell just finished charging — is the battery faulty?

Not likely. The BSM-4000's BMS is calibrated to a conditioned cell and reads a brand-new Ni-MH's internal resistance as insufficient capacity, even at full charge. Run one complete charge-to-discharge cycle first — this lets the BMS recalibrate its threshold to the new cell. If the alarm clears after that cycle, the battery is functioning correctly; if it persists, check that pack voltage reaches at least 12V on a multimeter before assuming a fault.

The monitor shuts off unexpectedly during patient transport after the battery swap — what's causing that?

New Ni-MH cells have higher internal resistance in their first 10 cycles, which causes voltage sag under the combined ECG, SpO₂, and display load the BSM-4000 draws during transport. The BMS interprets that sag as low charge and initiates a protective cutoff. Complete at least three full charge-discharge cycles before relying on the battery for transport use — voltage sag reduces significantly once the cell is broken in and capacity stabilises at its rated 3000mAh.

The charge indicator on the BSM-4000 won't reach 100% on the first charge with the new battery — should I be concerned?

No — the BSM-4000's charge IC applies a conservative upper limit on a new cell's first charge, often stopping at 85–95% indicated. This is the IC protecting the cell from overcharge before it has a stable charge history. Allow two full charge cycles without interrupting or unplugging the monitor mid-charge. By the second cycle, the IC adjusts its termination threshold and the indicator should reach the full charge state consistently.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.