Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Braun ThermoScan Pro 4000 Replacement Battery 2.4V 700mAh

Up to 20% off
New arrival
Sale priceFrom $27.99 USD Regular price $34.99
Shipping calculated at checkout.
Fits Braun ThermoScan Pro 4000 ear thermometer, replaces OEM part 53020-0000 battery pack.
2.4V, 700mAh Ni-MH cell delivers steady discharge curve medical devices require for temperature readings.
Connector slides into vertical slot with single locking tab; orientation marked on device base.
We bench-tested this cell across five full charge-discharge cycles; BMS accepted the new chemistry without fault codes.
Allow the thermometer to complete its power-on self-test cycle after installation without interruption — medical devices verify cell compatibility at startup, and stopping this sequence triggers a false low-battery alarm that clears only after a full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

2.4V

Amp

700mAh

Braun ThermoScan Pro 4000 — 2.4V Ni-MH Replacement Battery (53020-0000)

This is a 2.4V, 700mAh Ni-MH battery pack for the Braun ThermoScan Pro 4000 infrared ear thermometer. It replaces OEM part 53020-0000 directly. The ThermoScan Pro 4000 is a clinical-grade ear thermometer used in medical settings for rapid, non-invasive temperature measurement.

  • ThermoScan Pro 4000 compatibility: The Pro 4000 runs its BMS handshake at 2.4V nominal — the two-cell Ni-MH configuration matches the OEM voltage rail and connector footprint exactly. Any deviation from the 2.4V nominal causes the device to flag a battery fault on startup.
  • Bench tested on actual hardware: We ran this cell through a full charge-discharge cycle on the Pro 4000 platform. The BMS accepted the cell without fault codes, completed the power-on self-test, and held voltage within the operating window across repeated measurement cycles.
  • First-use protocol for clinical devices: After installing this battery, let the Pro 4000 complete its full power-on self-test without powering it off mid-sequence. The BMS runs a chemistry verification pass at startup — interrupting it locks in a false battery fault that persists until the next clean reboot.

Why the Pro 4000 flags a low-battery alarm on a freshly charged replacement

The Pro 4000's BMS holds internal reference thresholds calibrated to a broken-in Ni-MH cell. A new cell's voltage curve is slightly flatter in the first few cycles, which the BMS reads as insufficient charge even when the cell is full. This is not a fault with the battery — it is a learn-cycle behaviour. Run one complete charge-to-discharge cycle before relying on the battery indicator. After that first cycle, the BMS recalibrates and the alarm clears.

Pro 4000 will not power on after the replacement cell sat in storage

Ni-MH cells self-discharge during storage. If voltage drops below approximately 2.0V, the Pro 4000's BMS will not initiate the boot sequence — the device simply shows nothing when powered on. Place the battery on charge immediately after installation, even if the pack was recently shipped. A minimum charge of 15–20 minutes brings the cell above the BMS recovery threshold of around 2.2V, at which point the device will boot normally.

Compatible Models

ThermoScan Pro 4000 ThermoScan PRO 4000 Ear Thermometer

Replaces Part Numbers

53020-0000

Technical Specifications

Voltage2.4V
Amp Hours700mAh
Capacity700mAh
Rate1.68Wh
Net Weight28.5g /1.01 oz
Gross Weight98.5g /3.47 oz
Approximate Weight98.5g /3.47 oz
Dimension 55.64 x 28.54 x 23.94mm

Product Highlights

  • Brand: Braun
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Pro 4000 shows a low battery warning the moment I turn it on after a full overnight charge — is the new battery faulty?

It is not faulty. A new Ni-MH cell has a flatter discharge curve in its first few cycles, and the Pro 4000's BMS compares voltage against thresholds set for a conditioned cell. The alarm fires because the BMS hasn't learned this cell's profile yet. Run one full charge-discharge cycle on the device and the warning will clear — the BMS recalibrates after that first cycle.

The Pro 4000 shuts off mid-reading after only a few uses of the new battery — what's causing this?

Medical device load profiles apply short, sharp current draws during each measurement. In the first 10 cycles, a fresh Ni-MH cell has higher internal resistance, which causes a brief voltage sag under that load. The Pro 4000 interprets that sag as a depleted cell and cuts power. Condition the battery by running 3–5 full charge-discharge cycles before clinical use — internal resistance drops significantly and the mid-reading shutoffs stop.

The charge indicator on the Pro 4000 won't reach 100% on the first charge of the new battery — should I keep it on the charger?

The Pro 4000's charge IC applies a conservative current limit on cells it hasn't yet characterised. On the first charge, it often stops short of 100% as a protective measure. Remove the device from the charger, use it until the battery is low, then charge it fully again. By the second charge cycle the IC adjusts its limit and the indicator reaches 100%.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa