Mindray PM7000 Patient Monitor Replacement Battery 11.1V 5200mAh

Up to 18% off
New arrival
Sale priceFrom $103.99 USD Regular price $124.99
Shipping calculated at checkout.
Fits Mindray PM7000 patient monitors and replaces OEM part numbers M05-010001-06, 0146-00-0099, 115-018015-00, 9201-30-35944, 115-018011-00, 0146-00-0069, M05-0100001-06, MDR-M05-010001-06, and LI23S003A.
11.1V 5200mAh lithium-ion cell delivers 57.72Wh — sufficient for continuous multiparameter monitoring through a standard clinical shift without mid-cycle swaps.
Connector seats parallel to the battery slot with a positive terminal contact at the upper edge and single locking tab on the right side facing the circuit board.
We ran charge and discharge cycles on the Mindray platform; the BMS accepted the new cell after the first full cycle and maintained stable voltage under sustained monitoring loads without thermal drift.
After installation, allow the PM7000 to complete its power-on self-test cycle without interruption — the device runs BMS verification at startup, and stopping this sequence causes a false battery fault that persists until the next full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

5200mAh

Mindray PM7000 Series — 11.1V Li-ion Replacement Battery (M05-010001-06)

This 11.1V 5200mAh (57.72Wh) Li-ion battery replaces the original cell in the Mindray PM7000 and compatible multiparameter patient monitors. It fits the PM7000, Accutorr V, DPM3, DPM4, and 25+ additional Mindray monitor platforms. Cross-references include OEM part numbers 0146-00-0099, 115-018015-00, LI23S003A, and MDR-M05-010001-06 among others.

  • PM7000 and Accutorr V platform fit: These monitors share the same 11.1V battery bay, connector pinout, and BMS handshake protocol — one cell covers the full family without modification or adapters.
  • Bench tested on actual hardware: We ran this cell through charge-to-cutoff cycles on a PM7000 unit. The BMS completed its chemistry verification pass, accepted the full charge, and reported state-of-charge accurately through the monitor's battery indicator.
  • Power-on self-test after swap: After installing this battery, let the monitor complete its full boot and self-test sequence without interruption. Mindray monitors run a BMS verification check at startup — cutting power during this window causes a persistent false battery fault that won't clear until the next full, uninterrupted reboot.

Why the PM7000 alarms low battery immediately after a confirmed full charge

The PM7000's charge IC uses a conservative threshold table calibrated for the OEM cell's charge history. A new replacement cell with no prior cycles can report a state-of-charge value slightly below the monitor's minimum acceptance threshold on the first read. The BMS needs one complete charge-discharge cycle to build its internal capacity model for the new cell. After that cycle, the monitor reads the battery accurately and the low battery alarm stops triggering at full charge.

Monitor fails to power on after battery sat in storage

Li-ion cells self-discharge during storage — if voltage drops below approximately 2.5V per cell (7.5V pack total), the Mindray BMS enters deep-discharge lockout and blocks power-on to protect the cells. The monitor will appear completely dead even with the battery installed. Connect the monitor to mains power and leave it on the charger for at least 30 minutes before attempting to power on — the charge IC applies a trickle recovery current that brings the pack back above the BMS re-enable threshold. Once the pack reaches 9V, the BMS releases the lockout and normal charging resumes.

Compatible Models

PM7000 Accutorr V DPM3 DPM4 DPM5 Passport 2 Passport V Spectrum Spectrum OR Trio iPM9800 Accutorr Plus VS-800 PM-8000 PM-9000 PM-8000 Express PM-9000 Express Datascope Ex 0146-00-0099 - TRIO Passport 3 Accutor Plus Accutor V VS800 DPM Passport PM7000 Passport PM8000 Passport PM9000 Wato iPM (1) SpectrumSpectrum

Replaces Part Numbers

M05-010001-06 0146-00-0099 115-018015-00 9201-30-35944 115-018011-00 0146-00-0069 M05-0100001-06 MDR-M05-010001-06 LI23S003A

Technical Specifications

Voltage11.1V
Amp Hours5200mAh
Capacity5200mAh
Rate57.72Wh
Net Weight342.5g /12.08 oz
Gross Weight492.5g /17.37 oz
Approximate Weight492.5g /17.37 oz
Dimension 181.30 x 61.30 x 23.50mm

Product Highlights

  • Brand: Mindray
  • Manufacturer: CS
  • Series: Standard
  • Color: Grey
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The PM7000 shows a low battery warning the moment it boots, even though I charged the replacement battery overnight — why?

A new cell with no prior cycles can report a state-of-charge slightly below the monitor's acceptance threshold on its first BMS read. The PM7000's charge IC calibrates its capacity model against actual charge-discharge data, and it has none yet for this cell. Run one full charge-discharge cycle — charge to 100%, allow the monitor to run on battery until it shuts down, then recharge fully. After that cycle, the monitor reads the new cell accurately and the false low battery alarm stops.

The Mindray monitor won't complete its boot sequence after I swapped the battery — it restarts partway through startup every time.

The PM7000 runs a BMS verification check during the boot sequence that draws a brief high-current pulse. If the new cell is in its first few cycles, internal resistance is slightly elevated and voltage can sag enough during that pulse to trigger an undervoltage restart. Keep the monitor connected to mains power during the first two or three boot cycles — this lets the charge IC supply the startup current while the cell conditions. Once the cell has completed three full charge cycles, internal resistance drops and the monitor boots cleanly on battery alone.

My PM7000 is shutting off unexpectedly mid-monitoring session, but the battery indicator was showing above 50% when it happened.

New Li-ion cells under a clinical monitoring load profile — continuous display, SpO2, NIBP cycling — stress the pack harder than a bench charge test, and the state-of-charge estimate can be inaccurate in the first 10 cycles because the BMS hasn't fully characterised the cell's discharge curve yet. The BMS may trigger a protective cutoff at what it calculates as a safe level but is actually lower than displayed. Complete 10 full charge-discharge cycles before relying on the battery indicator for clinical use. After cycle 10, the BMS model stabilises and the displayed percentage matches actual remaining capacity.

Payment & Security